INSTALLATION-DK 16 KSU & PCB

SECTION 100-816-205

MARCH 1993

TABLE 5-D

PESU CONTROLS AND INTERFACE CONNECTORS

CONTROL/INDICATOR/

TYPE OF COMPONENT

DESCRIPTION

CONNECTOR (Figure 5-16)

 

 

 

 

 

Off-hook Call

10-pin connector

Interface connector for optional Off-hook

Announce P10

 

Call Announce subassembly

 

 

connector (used in conjunction with P20,

 

 

P40, P50, and P60).

 

 

 

Off-hook Call

10-pin connector

Interface connector for optional Off-hook

Announce P20

 

Call Announce subassembly

 

 

connector (used in conjunction with P10,

 

 

P40, P50, and P60).

 

 

 

Off-hook Call

10-pin connector

Interface connector for optional Off-hook

Announce P40

 

Call Announce subassembly

 

 

connector (used in conjunction with P10,

 

 

P20, P50, and P60).

 

 

 

Off-hook Call

10-pin connector

Interface connector for optional Off-hook

Announce P50

 

Call Announce subassembly

 

 

connector (used in conjunction with P10,

 

 

P20, P40, and P60).

 

 

 

Off-hook Call

10-pin connector

Interface connector for optional Off-hook

Announce P60

 

Call Announce subassembly

 

 

connector (used in conjunction with P10,

 

 

P20, P40, and P50).

 

 

 

Ring Voltage Jumper

Three-terminal jumper

Sets ring generator voltage level for

Plug P90

 

circuits 1 and 2.

 

 

H = 190V P-P (factory setting)

 

 

L = 130V P-P

 

 

 

BGM W7 Jumper Pack

White jumper wire

When cut, configures PESU, circuit 8,

 

 

for BGM source connection.

 

 

 

 

 

 

3)Apply firm, even pressure to the EOCU to ensure proper mating of connectors.

4)Use 3-pair cable for connecting the PESU and the OCA electronic telephone (refer to Wiring Diagrams, Section 100-816-208, for wiring/ interconnecting details).

5)Refer to Station Apparatus Installation, Sec- tion 100-816-206,for procedures to add OCA to electronic telephones.

10.13Background Music (BGM) Configura- tion. Configure the PESU to support a BGM source in accordance with the following steps:

1)Remove the PCB from its protective packag- ing.

2)Cut the W7 (BGM) jumper wire on the PESU PCB.

3)Refer to Peripherals Installation, Section 100- 816-207, for BGM installation procedures.

10.14External Amplifier Configuration. The PESU does not have to be configured to support an