Disconnect Timer:

01 DISA 12:24 00:04;57 (incoming)

03 DISA 12:24 00:04;57 (outgoing)

6.03System Program Data Printout. If a printer is connected to the SMDR port on the QSMU, PIOU, or PIOUS, customer program information stored in the system RAM may be printed out for reference by using Program 97 (see Paragraph 6.14).

6.10SMDR Hardware Requirements

6.11The DK8 system must be equipped with a QSMU option PCB. QSMU Program 10-3, LED 04 must be OFF. Install the QSMU PCB in accordance with Section 100-816-204and wire the SMDR device to the QSMU (PPTC/mocular cord) in accor- dance with Section 100-816-208. The DK16 sys- tem must be equipped with a PIOU or PIOUS PCB in the Expansion Unit to support the SMDR printer/ call accounting device option. Connection of the printer or call accounting device to the PIOU or PIOUS PCB is accomplished with a 3-pair modular cord (7 feet maximum) and a PPTC connector adaptor (refer to Figure 7-20 for details). Call record data is ASCII-formatted, 8 bits, no parity, 1-stop bit.

6.12The DK8 KSU and DK16 PIOU or PIOUS contains a call record buffer which stores call record data (for 20 calls on DK8 or 50 calls on DK16) when the printed or call accounting device is turned off, or when no device is connected to the SMDR port. No further call records are stored after the buffer is filled. When the printer or call account- ing device is made operational, an “ERROR BUFFER OVERFLOW” message is printed to indi- cate that the buffer was full, and that some call information may have been lost.

6.13SMDR Programming Considerations

6.14Selectable programming options for the SMDR printer or call accounting device are:

Program 60

Item 2—Determines the length of time a call must be active before it will be registered by SMDR.

INSTALLATION-PERIPHERALS

SECTION 100-816-207

MARCH 1993

Item 3—Selects the records of outgoing calls or outgoing and incoming calls to be printed.

Item 4—Selects digit length of account code (4 to 15 digits).

Item 5—Allows only long distance call records to be printed.

Program 97

Allows system program data to be printed via the SMDR port (refer to Figure 7-21 for an example printout).

NOTES:

1.An SMDR printer must be connected to the SMDR port to use the printout option selected by Program 97.

2.Call record data is lost when program data is printed out using Program 97.

6.20SMDR Printer/Call Accounting Device In- stallation

6.21Install the SMDR printer/call accounting de- vice option in accordance with the following steps (refer to Figures 7-20, 8-26, and 8-24):

1)Connect the interface cable and the PPTC adaptor from the DK8 QSMU or DK16 PIOU or PIOUS SMDR port to the SMDR printer or call accounting device DB25 connector.

2)Set the DK16 PIOU or PIOUS SW1 switch to the appropriate baud rate (300 or 1200 bps), as determined by the baud rate of the printer or call accounting device. For DK8, QSMU is always 1200 bps.

3)The DK8 QSMU Program 10-3, LED 04 must be OFF for SMDR operation.

4)Set the printer or call accounting device to 8- bits/no parity/one stop bit.

5)Program (Program 60) the system for the required SMDR printer/call accounting device options (refer to Paragraph 6.13 and the Pro- gramming Procedures, Section 100-816-300).

7-27