INSTALLATION-PERIPHERALS
SECTION 100-816-207
MARCH 1993

7-28

FIGURE 7-20

DK8 AND DK16 PIOU/PIOUS SMDR CABLE CONNECTIONS

BASIC CONNECTION
3-pair
Modular
Cord (7 ft. max)
SMDR
Modular
Jack
Modular
Jack
Toshiba
PPTC1A-5M,
RS232, Modular
to DB25 Adaptor
DB25
Plug
BASIC WIRING (see: QSMU PIOU or PIOUS TTY and SMDR Wiring in Chapter 8 for more detail)
PIOU, SMDR Jack
Modular Pin No.
1
2
3
4
5
6
Modular Pin No.
6
5
4
3
2
1
DB25 Pin No.
3
2
6
20
8
7
4 Jumper to 5
RS-232
Lead Name
RD
TD
DSR
DTR
CD
SG
RTS to CTS
50 ft. max
24 AWG Wire
Twisted Pair
Modularized
PPTC1A-5M Adaptor
To
To
To
To
To
To
To
To
To
To
To
To
DATA FORMAT:
• ASCII
• 8-bits
• No parity
• 1-stop bit
• QSMU: 1200 bps
• PIOU/PIOUS 300 or
1200 bps
DK8, QSMU*
DK16, PIOU
or
DK16, PIOUS
Printer
or Call
Accounting
Device
*QSMU,
PROGRAM 10-3
LED 04-OFF

7 VOICE MAIL OPTIONS

7.00 System Hardware Requirements
7.01 The STRATA DK8 and DK16 may be config-
ured to support Toshiba VP voice mail messaging
system or a customer-supplier voice mail system.
7.02 The DK8 must be equipped with a QSTU, and
the DK16 must be equipped with a KSTU, PSTU, or
PESU to support a voice mail system. The DK8
QSTU is equipped with two standard telephone
circuits; the DK16 KSTU is equipped with four
standard telephone circuits, the PSTU with eight,
and the PESU with two. A K4RCU subassembly
must be installed in the DK16 Base Unit, and a
QRCU must be installed in the DK8 KSU. The voice
mail system can be connected to any standard
telephone circuit at the MDF block.
7.10 Toshiba VP Voice Messaging System
7.11 The STRATA DK8 and DK16 is designed to
support the full range of features offered by the
Toshiba VP provides various call routing, message
handling, and information management features,
including:
Automated Attendant
Call Forward to Voice Mailbox
Message Waiting Indication