TO BASE UNIT (P5)

W/FEMALE CONNECTOR

BRIDGING

CLIPS

W-BL

26

 

1

 

 

1

BL-W

1

 

 

 

 

 

 

W-O

27

2

 

 

2

 

 

 

 

O-W

2

3

 

 

3

 

 

 

 

W-GN

28

4

 

 

4

 

 

 

 

GN-W

3

5

 

 

5

 

 

 

 

W-BR

29

6

 

 

6

 

 

 

 

BR-W

4

7

 

 

7

 

 

 

 

W-S

30

8

 

 

8

 

 

 

 

9

9

 

 

INSTALLATION-WIRING DIAGRAMS

SECTION 100-816-208

MARCH 1993

STATION CABLING

JACKETED TWISTED PAIRS

(-)

 

T1 (VOICE/DATA)4

24AWG (1 OR 2 PAIR, SEE NOTE 2)

 

 

 

(GND)

R1 (VOICE/DATA)

 

 

(-)

 

PT1 (ADD, POWER)

 

 

(GND)

PR1 (ADD. POWER)

 

 

T2

 

 

 

 

R2

CIRCUIT 2 TO DKT24

R

GN

PT2

OR PDIU-DS

 

 

PR2

R1

T1

 

T3

 

 

BK

Y

 

S-W

5

 

 

 

 

 

10

 

 

10

 

R-BL

31

 

 

 

 

 

 

 

 

BL-R

6

11

 

 

11

 

 

 

 

 

 

R-O

32

12

 

 

12

 

 

 

 

 

 

O-R

7

13

 

 

13

 

 

 

 

 

 

R-GN

33

14

 

 

14

 

 

 

 

 

CONNECTOR

GN-R

8

15

 

 

15

 

 

 

 

R-BR

34

16

 

 

16

 

 

 

 

BR-R

9

17

 

 

17

 

 

 

 

R-S

35

18

 

 

18

 

 

 

 

S-R

10

19

 

 

19

 

 

 

 

AMP

BK-BL

36

20

 

 

20

 

 

 

 

BL-BK

11

21

 

 

21

W/MALE

 

 

 

 

BK-O

37

22

 

 

22

 

 

 

 

O-BK

12

23

 

 

23

 

 

 

 

BK-GN

38

24

 

 

24

 

 

 

 

CABLE

GN-BK

13

25

 

 

25

 

 

 

 

BK-BR

39

26

 

 

26

 

 

 

 

-PAIR

BR-BK

14

27

 

 

27

 

 

 

 

BK-S

40

28

 

 

28

 

 

 

 

29

 

 

29

25

S-BK

15

 

 

 

 

30

 

 

30

 

Y-BL

41

 

 

 

 

 

 

 

 

BL-Y

16

31

 

 

31

 

 

 

 

 

 

Y-O

42

32

 

 

32

 

 

 

 

 

 

O-Y

17

33

 

 

33

 

 

 

 

 

 

Y-GN

43

34

 

 

34

 

 

 

 

 

 

GN-Y

18

35

 

 

35

 

 

 

 

 

 

Y-BR

44

36

 

 

36

 

 

 

 

 

 

BR-Y

19

37

 

 

37

 

 

 

 

 

 

Y-S

45

38

 

 

38

 

 

 

 

 

 

S-Y

20

39

 

 

39

 

 

 

 

 

 

V-BL

46

40

 

 

40

 

 

 

 

 

 

BL-V

21

41

 

 

41

 

 

 

 

 

 

V-O

47

42

 

 

42

 

 

 

 

 

 

O-V

22

43

 

 

43

 

 

 

 

 

 

V-GN

48

44

 

 

44

 

 

 

 

 

 

GN-V

23

45

 

 

45

 

 

 

 

 

 

V-BR

49

46

 

 

46

 

 

 

 

 

 

47

47

 

 

 

R3

PT3

PR3

T4

R4

PT4

PR4

T5

R5

PT5

PR5

T6

R6

PT6

PR6

T7

R7

PT7

PR7

T8

R8

PT8

PR8

R1

T1

R1

T1

CIRCUIT 3 TO DKT34

OR PDIU-DS OR DDCB

CIRCUIT 4 TO DKT44

OR PDIU-DS OR DDCB

CIRCUIT 5 TO DKT55

OR PDIU-DS

CIRCUIT 6 TO DKT65

OR PDIU-DS

CIRCUIT 7 TO DKT75

OR PDIU-DS

CIRCUIT 8 TO DKT85

OR PDIU-DS

RELAY

CONTACTS

NOT USED

STD TEL3

CIRCUIT 1

NOT USED

STD TEL

CIRCUIT 2

OR BGM

PT1

 

 

 

 

 

PR1

 

 

 

W

 

 

 

 

BL

 

 

RJ11

 

 

 

 

 

 

 

 

 

 

6

5

4

3

2

1

 

 

 

 

 

2

3

4

5

 

 

 

 

 

PR

TR

PT

GND

(-)

GND

(-)

MODULAR

 

 

 

 

 

PR

T

R

PT

CORD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIGITAL

 

 

 

 

 

 

 

 

 

TELEPHONE (DKT 1)

 

 

 

 

 

 

 

(WITH OR WITHOUT ADM,

 

 

 

 

 

 

PDIU-DI/PDIU-DI2)

 

NOTES:

1.Voltage levels:

T, PT = -26.3 ~ 27.8 VDC R, PR = 0.0 VDC (GND) (Reference to FG Ground

2.T/R wires are always required; PT/PR are additional power wires required only for long station runs per Table 8-D. PT/PR may be used with normal station runs also.

3.Standard Telephone circuits 1 ~ 2 require a QSTU to be installed.

4.DKT circuits (1 ~ 4) are standard on the DK8 main PCB.

5.DKT circuits (5 ~ 6) require one optional QCDU circuit and DKT circuit (7 ~ 8) require a second QCDU to be installed.

BR-V

24

 

 

 

 

 

V-S

50

48

 

 

48

 

 

 

 

 

 

S-V

25

49

 

 

49

 

 

 

 

 

 

 

 

50

 

 

50

 

66M150 SPLIT BLOCK

NOT USED

FIGURE 8-2

DK8 MDF WIRING TO KSU AMPHENOL STATION AND RELAY CONNECTIONS

8-7

Page 201
Image 201
Toshiba DK 16 manual DK8 MDF Wiring to KSU Amphenol Station and Relay Connections