INSTALLATION-PERIPHERALS SECTION 100-816-207 MARCH 1993

DK16 KDCU, CKT1

- OR-

DK16 PDKU, CKT1

- OR -

DK16 DIGITAL CKT5 OF BASE UNIT

- OR -

DK8 KSU, CKT 3 AND 4

 

DDCB

 

NOTE 1

A

2

RELAY

 

 

3

CONTROL

 

 

 

CONTACT

 

4

 

 

5

(See Fig. 8-4

B

 

 

 

wiring diagrams)

 

3

(DK16 Port 04, 12)

 

4

(DK8 Port 02, 03)

 

 

 

DOOR LOCK

C

 

 

3

CONTROL

 

 

 

CONTACT

 

 

NOTE 2

 

4

RJ11

3

1

MDFB

 

4

2

DOOR PHONE

 

 

 

 

2

TO CUSTOMER

A

 

5

 

 

SUPPLIED

 

 

 

 

RJ11

 

DEVICE

MDFB

3

1

 

 

DOOR PHONE B

 

 

- or -

4

2

DOOR LOCK CONTROL

 

RJ11

3

1

MDFB

 

 

 

DOOR PHONE

 

4

 

C

 

2

 

DDCB TO DK8 KSU WIRING CHART

PORT NO.

DK8 AMPHENOL

TO

DDCB

KSU JACK

 

 

 

 

 

 

02

DT (30) / DR (5)

TO PIN 3 / 4

 

PT (31) / PR (6)

TO PIN 5 / 6

 

 

 

03

DT (32) / DR (7)

TO PIN 3 / 4

 

PT (33) / PR (8)

TO PIN 5 / 6

 

 

 

 

NOTES

1.Relay control contact will close when the door phone is in the ringing, talk, or monitor state.

2.See Paragraph 4.25 for Door Lock assignments.

3.Relay contact specifications are -24VDC at 1.0 amp. max. Do not connect relay contacts to 120 AC commercial power.

DDCB TO DK16 BASE UNIT WIRING CHART

BASE UNIT

TO

DDCB KSU JACK

AMPHENOL

 

 

DT (34) / DR (9)

TO

PIN 3 / 4

PT (35) / PR (10)

TO

PIN 5 / 6

 

 

 

DDCB TO DK16 EXPANSION UNIT

WIRING CHART

KCDU OR PDKU

TO

DDCB KSU JACK

 

 

 

DT (26) / DR (1)

TO

PIN 3 / 4

PT (27) / PR (2)

TO

PIN 5 / 6

 

 

 

See Figure 8-4for DK16 Base Unit, PDKU, and KCDU pin-out information

FIGURE 7-9

DK8 AND DK16 DOOR LOCK CONTROL OPTION (DDCB)

5)Access Programs 29-1~ 29-2to program a

Night Transfer button (NT1 or NT2) on all DSS consoles that are to transfer the system into the NIGHT mode.

6)If tenant operation is required, access Pro- gram 15 to set the CO lines for tenant 1 (NT1) or tenant 2 (NT2) operation.

7A) Set the P11 jumper plug on the PIOU to the

MAKE or BREAK position, as required:

MAKE—Shorts the normally open con- tacts (pins 9 and 34) when the night relay is activated.

BREAK—Opens the normally closed contacts (pins 9 and 34) when the night relay is activated.

7B) Solder the jumper W2 on the PIOUS to the

MAKE or BREAK position, as required:

MAKE—Shorts the normally open con- tacts (NHT and NHR) when the night relay is activated.

BREAK—Opens the normally closed contacts (NHT and NHR) when night relay is activated.

8)Refer to Figures 7-6 and 7-7 for wiring/inter- connecting details. Connect the PIOU or PI- OUS to the MDF as required for the night relay function.

NOTE:

Door phones programmed to ring over exter- nal page in night mode (Program 77-1) do not activate the NT relay.

7-11

Page 143
Image 143
Toshiba DK 16 DK8 and DK16 Door Lock Control Option Ddcb, Ddcb to DK8 KSU Wiring Chart Port no DK8 Amphenol KSU Jack