REMOTE ADMINISTRATION AND MAINTENANCE PROCEDURES
SECTION 100-816-600
MARCH 1993
-8-
continuing with Remote Administration and
Maintenance installation.
5) If a terminal is to be utilized on-site, refer to
Paragraph 5. For off-site programming refer to
Paragraph 6.
5 LOCAL TERMINAL OPERATION
5.00 Requirements
5.01 For DK16, the optional Expansion Unit must
have a PIOU or PIOUS PCB installed to perform
on-site Remote Administration from a local termi-
nal. For DK8, a QSMU PCB is required. Paragraph
4 and Figure 5 provide installation details on local
terminal installation.
5.02 The local terminal for either the STRATA
DK16 or the DK8 must have an EIA RS-232 inter-
face, communicate in ASCII code at 300 or 1200
bps (1200 bps only for DK8), have a standard
typewriter-type keyboard, and display data via a
CRT display or printer. A personal computer (PC)
capable of emulating the described terminal with a
communications software package (such as
PROCOMM) may also be used (Figure 5).
5.03 Operating the PC or terminals, local or re-
mote, is identical. The only difference is the physi-
cal connection and the method used to establish
initial communications.
5.10 Set-up
5.11 Refer to Figure 2 and verify that the local
terminal is connected and set-up as follows:
1) Connect the RS-232 cable to the terminal
connector and the PIOU(S) or QSMU TTY
connector.
NOTE:
If a personal computer is being used, connect
the cable to the serial “COM” port.
2) Set the PC or terminal baud rate to match the
DK16 SW2 PIOU(S) setting (300 or 1200 bps)
or the DK8 QSMU setting (1200 bps).
3) Set the terminal for “Full Duplex” operation.
4) Set the keyboard for “Caps Lock” on.
5) Set the parameters of the terminal (or modem)
connected to the TTY to:
Word length: Seven bits
Stop bits: One
Parity: Even
5.20 Local Operation
5.21 Use the procedure below to establish com-
munications between the local terminal and the
PIOU(S) or the QSMU so that programming may be
accomplished via the terminal.
NOTE:
Hereafter, whenever the term
CR
is used, it
means the return or enter key, depending on
the keyboard being used.
SPACE
means the
space bar. An empty square indicates one of
several characters will appear in that location
(either on the terminal screen or in a printout).
1) Set-up the terminal as described in Paragraph
5.10.
2) Set the terminal to on-line.
3) Set “Caps Lock” on (upper case).
4) Press CR key.
The system responds, and the terminal
displays:
DK CONNECT
> CODE
5) Type the four-digit security code, and press
CR. (Default code = 0000.)
The system responds, and the terminal
displays:
OK
MODE
NOTE:
The security code can be entered any time the
CODE prompt appears.
6) To continue, go to Paragraph 7.
6 REMOTE TERMINAL OPERATION
6.00 Requirements
6.01 Terminal: For the STRATA DK8 or the
STRATA DK16, the terminal must interface with an