REMOTE ADMINISTRATION AND MAINTENANCE PROCEDURES
SECTION 100-816-600
MARCH 1993
-15-

IMPORTANT NOTE:

For DK16 only: If all programs are initialized, the "IMDU enabled" has also been turned off in

Program 77-1

, LED 14. If using the IMDU for remote programming, go into

Program 77-1

and turn

button/LED 14 on as shown in steps 9, 10, and 11. If this is not completed, remote programming

must be reactivated locally from the programming digital or electronic telephone.

TABLE RM-D
PROGRAM 90INITIALIZING PROGRAMS 00 ~ 97
ACTIONSTEP DISPLAY/PRINTOUT
1>MODE PROGEnter the Program Mode
At the >MODE prompt enter P R O G CR.
2P 90
P90
Enter Program Number 90
Press CR.
3P90 00
*
97To Initialize All Programs Enter 0 0
*
9 7
NOTE: Single programs can be initialized by entering a single
program number plus
#.
Group numbers are separated by an
*
.
4P90 00
*
97 01 NEnter button/LED number 0 1.
5P90 00
*
97 01 N YChange 01 button/LED to “ON” by entering Y.
7
8 Press CR.
Press SPACE.6
P90 00
*
97 01 N Y
02 N Y
Initialization complete. P90 00
*
97 01 N
P90 02 N Y
P90 00
*
97 01 N Y
02 N
9
10
11
12
Exit Program 90
Press # # CR.P90 #
P
For DK16, Enter Program 77
Press 7 7 CR.P77
then: Y CR.
Press 1 1 4.P77 1 14 N
P77 1 14 N Y
P77
To Exit this Program:
Press # # CR.
NOTE: If program data is not entered correctly, then
CR
will
not respond. To retry, press
DELETE CR.
Change LED 02 to “ON” by entering Y.