REMOTE ADMINISTRATION AND MAINTENANCE PROCEDURES

SECTION 100-816-600

MARCH 1993

TABLE RM-BS

STATION/CO LINE STATUS CHECK

STEP

 

ACTION

DISPLAY/PRINTOUT

 

 

 

1

Enter the Test Mode

>MODE TEST

 

At the >MODE prompt, enter T E S T CR.

 

 

 

 

2

To Check Station Line Status

T SEKT XX IDLE ON-HOOK

 

Enter

S E K T X X (X X = port number).

T

 

Possible status: Idle on-hook, idle off-hook, busy on-hook,

 

 

busy off-hook.

 

 

 

IMPORTANT!

 

 

To prevent service interference, station line status must be

 

 

idle on-hook before initiating a test from that station.

 

 

 

 

3

To Check CO Line Status

T SCOYY – BUSY

 

Enter S C O Y Y (Y Y = CO line number).

T

 

Possible status: Idle, busy.

 

 

 

 

4

To Exit the Test Mode

T QUIT

 

At the T prompt, enter Q U I T CR.

> MODE

 

 

 

 

 

 

TABLE RM-BT

 

 

 

GENERAL STATION ACCESS AND BUTTON ACTIVATION

 

 

 

STEP

ACTION

DISPLAY/PRINTOUT

 

 

1 Enter the Test Mode

>MODE TEST

 

At the >MODE prompt, enter T E S T CR.

T

 

 

2 To Activate A Button

T TKXX KYY

 

Enter T K X X K Y Y CR.

T

XX= Port number and YY = button number. NOTE: Button numbers begin at 01.

3

To Activate A Function Button

 

TTKXX F

 

Enter T K X X F CR F = function button designator

T

 

 

SPKR

S

 

 

 

 

 

HOLD

H

F = S, H, C, M

 

 

 

 

CONF

C

 

 

 

 

 

 

 

 

 

MIC

M

 

 

 

 

 

 

4

To Access A CO Line (via CO Access Code) and Dial Out

TTKXX K01 AAA

 

Enter T K X X K 0 1 A A A

CR.

T

AAA= 1, 2, or 3-digit CO line access code and = telephone number.

5 To Access A CO Line (via CO Line Button) and Dial Out

TTKXX KYY

Enter T K X X K Y Y

 

 

 

CR.

T

YY = CO line number.

 

 

Telephone Number

 

 

 

 

 

6To Exit the Test Mode

At T prompt, enter Q U I T CR.

-66-

Page 316
Image 316
Toshiba DK 16, DK8 manual Table RM-BS STATION/CO Line Status Check