INSTALLATION-PERIPHERALS SECTION 100-816-207 MARCH 1993

 

TBI

MDF

BREAK

 

 

DET

 

 

W1 MAKE

 

K1

DE

 

DER

 

BREAK

 

 

NHT

 

 

W2 MAKE

 

K2

NH

 

NHR

 

NORMAL OPEN

 

 

ALMT

 

ALARM

W3

 

SENSOR

ALM

 

 

ALMR

 

NORMAL

 

CLOSE

 

PIOUS

 

 

All wiring connections must be 24 AWG twisted pairs.

NIGHT BELL

DOOR

LOCK

CONTROL

MOH

SOURCE

UNIT

FACILITY

ALARM

UNIT

RELAY OPTIONS:

K1 (DE): DOOR LOCK OR AMP MUTE CONTROL; PROGRAM 77-1, LED 07

K2 (NH): NIGHT RELAY OR MUSIC-ON-HOLD CONTROL; PROGRAM 77-1, LED 05

K1 & K2: 24VDC, 1 AMP MAXIMUM

FIGURE 7-7

DK16 PIOUS RELAY CONTROL FUNCTIONAL WIRING DIAGRAM

3.25 Door Lock Assignments Guide

Host

Port

Door

Prog. 39

No.

Lock No.

Assignments

 

 

 

 

 

DK16 PIOU/PIOUS

N/A

0

Code 71

 

 

Unlock

 

 

 

Door 0

 

Ckt 5 DK16

04

1

Code 72

Base Unit DDCB

 

Unlock

 

Ckt 3 DK8 KSU DDCB

02

Door 1

 

 

 

 

 

Ckt 1 Expansion Unit

12

2

Code 73

(PDKU or KCDU)

 

Unlock

 

Ckt 4 DK8 KSU DDCB

03

Door 2

 

 

 

 

 

Note: CKT1 must be used in installing DDCB on KCDU or PDKU. (Must be in Port 12)

3.30DK16 Expansion Unit Night Transfer/ Music-on-Hold Relay Options with PIOU or

PIOUS

3.31The NHT/NHR relay may be programmed for either the night relay or the MOH relay function (refer to Figures 7-6 and 7-7). These functions can be provided in addition to the relay service provided by the Base Unit.

3.32When configured for the night transfer func- tion with Program 77-1, the relay activates if the system is in the NIGHT mode. The relay may be

7-9

Page 141
Image 141