INSTALLATION-SITE REQUIREMENTS

SECTION 100-816-202

MARCH 1993

TABLE 2-A

SUMMARY OF ELECTRICAL/ENVIRONMENTAL CHARACTERISTICS

GENERAL

Primary power

 

 

 

 

 

Input AC

85 ~ 135VAC

 

 

AC frequency

50/60 Hz

 

 

Power

DK8-46 watts maximum, DK16-75 watts maximum

 

 

 

 

 

 

Environmental specifications

 

 

 

 

 

Operating temperature

32 ~ 104°F (0 ~ 40°C)

 

Operating humidity

20 ~ 80% relative humidity without condensation

Storage temperature

- 4 ~ 158°F (-20 ~ 70°C)

 

 

 

 

 

 

 

Power supply

DK16

 

DK8

 

 

DC voltage output

 

 

 

+24VDC: (+26.3 ~ +27.8VDC)

–24VDC: (–26.3 ~ –27.8VDC)

specification

+5VDC: ( +4.5 ~

+5.5VDC)

+5VDC: ( +4.5 ~ +5.5VDC)

 

–5VDC: ( –4.5 ~

–5.5VDC)

Note: +5V converter

 

 

 

 

 

on KSU PCB

 

 

 

 

 

Battery charger characteristics

Charger: current limiting

 

(DK16 only)

Nominal float voltage: 2.275 volts/cell

 

Charge current: 0.7 amps maximum

 

Battery discharge cut-off voltage: 20.5 ± 0.5VDC

 

 

 

 

QSTU, KSTU, PSTU or PESU (circuits 1 & 2)

Square wave output with high/low option jumper:

Ring voltage

Low position, 130 ± 20VDC peak–to–peak (no-load)

 

High position, 190 ± 25VDC peak–to–peak (no-load)

Ringing capability

Two ringers maximum per circuit, high or low position

 

 

 

 

 

 

GROUND 1 THIRD WIRE GROUND

 

TO AC POWER CORD

THIRD WIRE

DK8 OR DK16 KSU

AC GROUND

 

 

POWER

 

SUPPLY

A

 

ELECTRICAL

 

SYSTEM GROUND

 

 

FG

FIGURE 2-4

KSU GROUNDING DIAGRAM

2)Connect the meter probes between the two main AC voltage terminals (white and black wires) on the wall outlet. The reading obtained should be between 100 ~ 120 VAC.

3)Move one of the meter probes to the third terminal (green wire ground). Either the same reading or a reading of zero volts should be obtained.

4)If the reading is zero volts, leave one probe on the ground terminal and move the other probe to the second voltage terminal.

CAUTION!

If a reading of zero volts is obtained on both voltage terminals (white wire to green wire, black wire to green wire), the outlet is not properly grounded. Omit steps 5 and 6, and proceed directly to step 7.

2-3

Page 17
Image 17
Toshiba DK8, DK 16 manual Summary of ELECTRICAL/ENVIRONMENTAL Characteristics, KSU Grounding Diagram, General