REMOTE ADMINISTRATION AND MAINTENANCE PROCEDURES SECTION 100-816-600

MARCH 1993

the station’s LCD and is automatically displayed on other stations’ LCDs whenever they call that sta- tion.

Mode 95: To edit and/or review a Calling Station Message before setting it, use this mode. It will display the existing message and allow additions to it (such as a time or a date) before it is set. (The message cannot be changed with this mode— just added to.)

At the P, D, T or R prompt, enter Q U I T CR and observe:

>MODE

13.03To exit the LCD Message (MESG) mode:

At anytime while in the message mode, enter: m

0 q and observe:

>MODE

NOTE:

To exit the Message Mode, the terminal key- board must be in lower case.

Mode 97: To add or change a Calling Station Message before setting it, use this mode. It does not display the existing message, but allows a completely new message to be entered before it is set.

11.22Use the procedures in the tables to set messages via Modes 94/96 and 95/97.

12SPEED DIAL MODE

12.00General

12.01The Speed Dial Mode (see Table RM-BW) can be used to add or change speed dial numbers to any of the System Speed Dial memory locations (60 ~ 99) and Station Speed Dial memory locations (10 ~ 49).

12.02Chain Speed Dial numbers can also be programmed using the Speed Dial Mode. See the Digital or Electronic Telephone User Guide for more information regarding chain Speed Dialing.

12.03To program Speed Dial numbers, enter the REPT mode per Paragraph 7 of this section. Then use the Speed Dial Mode Procedure at the end of this section.

13MODE EXIT

13.01Exit the current mode per Paragraph 13.02 and select the desired mode via Paragraph 7.

13.02To exit the Program (PROG), Data Dump (DUMP), Test (TEST) or Speed Dial (REPT) mode:

14DISCONTINUE OPERATION

14.00Local Terminal

14.01Exit current operating mode via Paragraph 13 and observe that the MODE prompt is displayed on the terminal.

14.10Remote Terminal

14.11Exit current operating mode via Paragraph 13 and observe that the MODE prompt is displayed on the terminal.

14.12To discontinue remote operation:

1)Take the terminal off-line.

2)Verify that the modem drops the line.

15 EQUIPMENT COMPATIBILITY

15.01Equipment that is known to be compatible with STRATA DK8 and DK16 Remote Administra- tion and Maintenance is listed as follows. This list does not show all of the equipment that will work, only the equipment that has been proven compat- ible in the field or lab.

Terminals

Texas Instruments: Silent 700

Panasonic: KXD-4920

Personal Computers with the PROCOMM com- munications software package.

Modems

Hayes compatible

-14-