REMOTE ADMINISTRATION AND MAINTENANCE PROCEDURES
SECTION 100-816-600
MARCH 1993
-14-
the station’s LCD and is automatically displayed on
other stations’ LCDs whenever they call that sta-
tion.
Mode 95: To edit and/or review a Calling Station
Message before setting it, use this mode. It will
display the existing message and allow additions
to it (such as a time or a date) before it is set. (The
message cannot be changed with this mode—
just added to.)
Mode 97: To add or change a Calling Station
Message before setting it, use this mode. It does
not display the existing message, but allows a
completely new message to be entered before it
is set.
11.22 Use the procedures in the tables to set
messages via Modes 94/96 and 95/97.
12 SPEED DIAL MODE
12.00 General
12.01 The Speed Dial Mode (see Table RM-BW)
can be used to add or change speed dial numbers
to any of the System Speed Dial memory locations
(60 ~ 99) and Station Speed Dial memory locations
(10 ~ 49).
12.02 Chain Speed Dial numbers can also be
programmed using the Speed Dial Mode. See the
Digital or Electronic Telephone User Guide for
more information regarding chain Speed Dialing.
12.03 To program Speed Dial numbers, enter the
REPT mode per Paragraph 7 of this section. Then
use the Speed Dial Mode Procedure at the end of
this section.
13 MODE EXIT
13.01 Exit the current mode per Paragraph 13.02
and select the desired mode via Paragraph 7.
13.02 To exit the Program (PROG), Data Dump
(DUMP), Test (TEST) or Speed Dial (REPT) mode:
At the P, D, T or R prompt, enter Q U I T CR and
observe:
>MODE
13.03 To exit the LCD Message (MESG) mode:
At anytime while in the message mode, enter: m
0 q and observe:
>MODE
NOTE:

To exit the Message Mode, the terminal key-

board must be in lower case.

14 DISCONTINUE OPERATION
14.00 Local Terminal
14.01 Exit current operating mode via Paragraph
13 and observe that the MODE prompt is displayed
on the terminal.
14.10 Remote Terminal
14.11 Exit current operating mode via Paragraph
13 and observe that the MODE prompt is displayed
on the terminal.
14.12 To discontinue remote operation:
1) Take the terminal off-line.
2) Verify that the modem drops the line.
15 EQUIPMENT COMPATIBILITY
15.01 Equipment that is known to be compatible
with STRATA DK8 and DK16 Remote Administra-
tion and Maintenance is listed as follows. This list
does not show all of the equipment that will work,
only the equipment that has been proven compat-
ible in the field or lab.
Terminals
Texas Instruments: Silent 700
Panasonic: KXD-4920
Personal Computers with the PROCOMM com-
munications software package.
Modems
Hayes compatible