REMOTE ADMINISTRATION AND MAINTENANCE PROCEDURES
SECTION 100-816-600
MARCH 1993
-48-

TABLE RM-AU

PROGRAM 46-10 ~ 40

TOLL RESTRICTION CLASS PARAMETERS

ACTIONSTEP DISPLAY/PRINTOUT
1>MODE PROG
P
Enter Program Mode
At the >MODE prompt, enter P R O G CR.
2P 46
P46
Enter Program Number 46
3P46 10Refer to the System Record Sheet and enter the Toll Restriction
class number (1 ~ 4). Then enter the number 0.
Example: Class 1, enter 1 0.
6To Exit Program/Store Data
Press CR.
4 Refer to the System Record Sheet and enter the required
button/LED number.
Example: Button number 11, enter 1 1. The system will display
the status of the button/LED.
P46 10 11 TABLE 1N
A)
B) To store data, press CR.
To exit this program, press # # CR.
5 Refer to the System Record Sheet and change if required (Y or N).
To access next button number, press SPACE.P46 10 11 TABLE1 N Y
12 TABLE2 N
P46 10 11 TABLE1 N Y
P46 ##
P
12 TABLE2 N