REMOTE ADMINISTRATION AND MAINTENANCE PROCEDURES

SECTION 100-816-600

MARCH 1993

TABLE RM-AU

PROGRAM 46-10 ~ 40

TOLL RESTRICTION CLASS PARAMETERS

STEP

ACTION

 

DISPLAY/PRINTOUT

 

 

 

1

Enter Program Mode

>MODE PROG

 

At the >MODE prompt, enter P R O G CR.

P

 

 

 

 

 

 

 

2

Enter Program Number 46

P 46

 

 

 

Press CR.

P46

 

 

 

 

 

 

 

3

Refer to the System Record Sheet and enter the Toll Restriction

P46

10

 

 

class number (1 ~ 4). Then enter the number 0.

 

 

 

 

Example: Class 1, enter 1 0.

 

 

 

 

 

 

 

 

4

Refer to the System Record Sheet and enter the required

P46

10

11 TABLE 1N

 

button/LED number.

 

 

 

 

Example: Button number 11, enter 1 1. The system will display

 

 

 

 

the status of the button/LED.

 

 

 

 

 

 

 

 

5

Refer to the System Record Sheet and change if required (Y or N).

P46

10

11 TABLE1 N Y

 

To access next button number, press SPACE.

 

 

12 TABLE2 N

 

 

 

 

 

6

To Exit Program/Store Data

P46

10

11 TABLE1 N Y

 

A) To store data, press CR.

 

 

12 TABLE2 N

 

B) To exit this program, press # # CR.

P46

##

 

 

 

P

 

 

 

 

 

 

 

-48-

Page 298
Image 298