REMOTE ADMINISTRATION AND MAINTENANCE PROCEDURES

SECTION 100-816-600

MARCH 1993

TABLE RM-BU

CO LINE TEST

STEP

 

ACTION

 

DISPLAY/PRINTOUT

 

 

 

 

1

Enter the Test Mode

 

>MODE TEST

 

At the >MODE prompt, enter T E S T CR.

 

 

 

 

 

2

To Verify Station/CO Line Status

 

T SEKT XX IDLE ON-HOOK

 

Station line status, enter S E K T X X (X X = station port).

T

 

CO line status, enter S C O Y Y (Y Y = CO line number).

T SCO YY IDLE

 

 

 

3

Call Remote Station B (from SEKT XX and CO line YY)

T TK XX KYY

 

Enter T K X X K Y Y

CR.

T

 

(

= station B’s telephone number)

 

 

 

Answer station B.

 

 

 

NOTE:

 

 

 

If the system is equipped with Music-on-hold, go to step 4. If the

 

 

line must be tested via a CO-to-CO connection, go to step 6.

 

 

 

 

 

4

A)

Press the Hold button on TK XX (station B on hold).

T TKXX H

 

 

Enter T K X X H CR.

 

T

 

B)

Listen at station B and check that the transmission from the

 

 

 

music source is acceptable.

 

 

 

C)

Press the Spkr button on TKXX (to release the call).

T TKXX S

 

 

Enter T K X X S CR.

 

T

 

 

 

5

Continue returning to step 2 until all CO lines are tested.

 

 

 

 

 

6

To Set Up A CO-to-CO Connection

 

T TKXX C

 

Press the Cnf/Trn button on T K X X.

T

 

Enter T K X X C CR.

 

 

 

NOTES:

 

 

 

1. Station B is connected via step 3.

 

 

 

2. Verify that Program 15-5allows CO-to-CO connections.

 

 

3. The next step must be completed immediately to avoid

 

 

 

dial tone timeout.

 

 

 

 

 

7

Call station C (or local time/weather) via CO line C.

T TKXX KYY

 

Enter: T K X X K Y Y

CR.

T

 

X X = CO line C’s button number and

= telephone number of

 

 

station C.

 

 

 

Answer station C (or verify time/weather connection) and go to

 

 

next step.

 

 

 

 

 

8

Press the Cnf/Trn button on STXX to establish a conference

T TKXX C

 

between all parties.

 

T

 

 

 

9

If you wish to tie the two CO lines together and hang up:

T TKXX C

 

Enter T K X X C CR.

 

TTKXX S

 

Enter T K X X S CR.

 

T

 

 

 

10

Continue returning to step 2 until all CO lines are tested.

 

 

 

 

 

11

To Exit the Test Mode,

 

 

 

At the T prompt, enter Q U I T CR.

 

 

 

 

 

 

 

-67-

Page 317