TABLE 8-D

DIGITAL TELEPHONE/DIU/DDSS CONSOLE/ADM/LOOP LIMITS

 

QPSU/KPSU

Maximum line length (24 AWG)

 

or

 

 

1 Pair plus

MODE

Battery Backup1

1 Pair

2 Pair

external power3

DKT Ringing

QPSU/KPSU

1000 ft (303 m)

1000 ft (303 m)

1000 ft (303 m)

 

 

 

 

(Volume Max)

Battery Backup

675 ft (204 m)

1000 ft (303 m)

1000 ft (303 m)

 

 

 

 

 

DKT with

QPSU/KPSU

1000 ft (303 m)

1000 ft (303 m)

1000 ft (303 m)

 

 

 

 

DVSU (OCA)

Battery Backup

495 ft (150 m)

1000 ft (303 m)

1000 ft (303 m)

 

 

 

 

 

DKT with HHEU

QPSU/KPSU

1000 ft (303 m)

1000 ft (303 m)

1000 ft (303 m)

or

 

 

 

 

Battery Backup

330 ft (100 m)

1000 ft (303 m)

1000 ft (303 m)

Carbon Handset

DKT with PDIU-DI/

QPSU/KPSU

495 ft (150 m)

1000 ft (303 m)

1000 ft (303 m)

 

 

 

 

PDIU-DI2

Battery Backup

165 ft (50 m)

675 ft (200 m)

1000 ft (303 m)

 

 

 

 

 

PDIU-DS

QPSU/KPSU

1000 ft (303 m)

1000 ft (303 m)

1000 ft (303 m)

 

 

 

 

Battery Backup

675 ft (204 m)

1000 ft (303 m)

1000 ft (303 m)

 

 

 

 

 

 

DKT with HHEU

QPSU/KPSU

495 ft (150 m)

1000 ft (303 m)

1000 ft (303 m)

 

 

 

 

and PDIU-DI/PDIU-DI2

Battery Backup

33 ft (10 m)

330 ft (100 m)

1000 ft (303 m)

 

 

 

 

 

 

DDSS2060A

QPSU/KPSU

1000 ft (303 m)

1000 ft (303 m)

1000 ft (303 m)

 

 

 

 

Battery Backup

500 ft (151 m)

1000 ft (303 m)

1000 ft (303 m)

 

 

 

 

 

 

DDCB

QPSU/KPSU

1000 ft (303 m)

1000 ft (303 m)

1000 ft (303 m)

 

 

 

 

Battery Backup

500 ft (151 m)

1000 ft (303 m)

1000 ft (303 m)

 

 

 

 

 

 

DKT with DVSU

QPSU/KPSU

1000 ft (303 m)

1000 ft (303 m)

1000 ft (303 m)

 

 

 

 

and HHEU

Battery Backup

165 ft (50 m)

1000 ft (303 m)

1000 ft (303 m)

 

 

 

 

 

 

DKT with ADM

QPSU/KPSU

675 ft (204 m)

1000 ft (303 m)

1000 ft (303 m)

 

 

 

 

Battery Backup

165 ft (50 m)

1000 ft (303 m)

1000 ft (303 m)

 

 

 

 

 

 

NOTES:

1.Battery backup applies to instances when the system is being powered by batteries exclusively.

2.Digital telephones and other digital devices can operate at maximum lengths with two pair wiring or an external power source.

3.See Figure 8-28for external power wiring.

4.Digital cable runs must not have the following:

§Cable splits (single or double) §Cable bridges (of any length)

§High resistance or faulty cable splices

8-4