FAULT FINDING

SECTION 100-816-500

MARCH 1993

CHART NO. 2

CATASTROPHIC FAULTS

START

 

 

Go to

NO

Is the system

 

 

completely

 

 

 

 

 

 

 

Chart 1

 

 

 

non-operational?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check system

 

 

 

 

 

 

 

hardware per

 

 

 

 

 

 

 

paragraph 6.01 for DK8

 

 

 

 

 

 

 

or 7.01 for DK16

 

 

 

 

 

 

 

of this section.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Was the fault

 

 

 

 

 

 

 

isolated by completing

 

 

 

 

 

 

 

the system hardware

 

 

 

 

 

 

 

check?

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Re-initialize the system

 

 

 

 

 

 

 

(Programs 90, 92, and

 

 

 

 

 

 

 

03) and re-check fault

 

 

 

 

 

 

 

using default program

 

 

 

 

 

 

 

data (do not enter

2-4

 

 

 

 

 

customer data base).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reprogram customer

 

 

 

 

 

2-6

data base, one program

 

 

 

 

 

 

 

at a time, and check

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to see if fault re-occurs.

 

 

 

 

 

 

 

 

 

 

 

YES

Was the

 

 

 

 

 

 

 

 

2-7

 

 

fault cleared

 

 

 

 

 

after re-initializing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the system?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

Does the fault

re-occur afterYES2-8entering customer

data base?

 

NO

Call your

 

 

 

technical support

END

group.

 

 

 

 

YES

Tag the defective

2-3

unit(s) and return

 

for repair.

 

END

NOTE:

Program 03 is not used for DK8.