REMOTE ADMINISTRATION AND MAINTENANCE PROCEDURES

SECTION 100-816-600

MARCH 1993

TABLE RM-K

PROGRAM 03

SLOT ASSIGNMENTS

STEP

ACTION

 

DISPLAY/PRINTOUT

 

 

 

1

Enter the Program Mode

>MODE PROG

 

At the >MODE prompt, enter P R O G CR.

P

 

 

 

 

 

2

Enter Program Number 03

P 03

 

 

Press CR.

P03

 

 

 

 

 

3

Enter the Slot Number

P03

 

 

Refer to the System Record Sheet and enter the desired

P03

00 91

 

slot number.

 

 

 

Example: Slot number 00, enter 0 0.

 

 

 

 

 

 

4

Enter the PCB Code Number

P03

 

 

Refer to the System Record Sheet and enter the desired

P03

00 91 92

 

PCB code number.

 

 

 

Example: PCB code 92, enter 9 2.

 

 

 

 

 

 

5

To Exit Program/Store Data

P03

 

 

A) To store data, press CR.

P03

00 91 92

 

B) Continue returning to Step 3 until all Program 03

P03

##

 

data is entered.

P

 

 

C) To exit this program, press # #, press CR.

 

 

 

 

 

6

Turn system power "OFF" for 5 seconds and then turn

Remote maintenance is disconnected.

 

power "ON" to store data in working memory (see Notes).

 

 

 

 

 

 

IMPORTANT NOTES:

1.This program only applies to DK16 and must be completed with on-site assistance (after installing PCBs, if any) because the system must be powered down momentarily after PCB code entry.

2.Even though PCB codes display as being changed, they are not entered into working memory until the system DC power is cycled OFF and ON.

3.If PCB codes are not entered into working memory by cycling DC power, PCB options will not function.

4.Only Program 03 requires the system power to be turned OFF and ON to store data into working memory.