REMOTE ADMINISTRATION AND MAINTENANCE PROCEDURES

SECTION 100-816-600

MARCH 1993

 

 

 

PUBLIC TELEPHONE

 

 

REMOTE SITE

 

NETWORK

STRATA DK16/DK8

 

PC OR

 

 

 

 

 

TERMINAL

 

 

 

 

 

RS-232

MODEM

CO LINE

CO LINE A

CO LINE A

 

 

 

 

 

(DK16: 300 or 1200 BPS)

 

IMDU OR EXT. MODEM

 

 

 

 

 

 

 

(DK8: 1200 BPS)

 

DATA

 

 

 

 

 

 

 

 

 

 

BUS

 

 

 

 

 

CPU

TOSHIBA

 

 

 

 

STATION

 

 

 

 

 

CKT

 

REMOTE

 

CO LINE

CO LINE B

CO LINE B

 

STATION B

 

 

 

 

 

 

 

 

 

Digital Telephone XX

REMOTE

 

CO LINE

CO LINE C

 

CO-to-CO

STATION C

 

 

 

CO LINE C

CONNECTION

 

 

 

TIME OR

 

 

 

 

 

WEATHER

 

 

FIGURE 8

TEST MODE FUNCTION DIAGRAM

2)Establish a talk path between a remote station and the time or weather service via a CO-to- CO connection through STRATA DK8 or DK16.

10.13The procedures in the tables provide ex- amples of the types of tests and functions that can be accomplished with the Test Mode. These proce- dures do not cover all the possible tests that can be performed remotely; however, by using the prin- ciples given, other tests are possible.

11LCD MESSAGE MODE

11.00General

11.01This mode allows a local or remote terminal to set Called and Calling Station LCD messages for station users (see Table RM-BO ~ BR). The mes- sages may be system or station type and are stored in their respective memory locations when set.

11.10Remote Called Station Message Mode

11.11Allows the terminal to set a Called Station Message for an originating station with the destina- tion of the message being a station or group of

stations.

11.12When the message is set, the Msg LED(s) on the destination station(s) flash.

11.13When a destination station calls the originat- ing station, the message is displayed on the desti- nation station’s LCD.

Mode 94: To edit and/or review a Called Station Message before setting it, use this mode. It will print out the existing message and allow addi- tions to it (such as a time or a date) before it is set. (The message cannot be changed with this mode—just added to.)

Mode 96: To add or change a Called Station Message before setting it, use this mode. It does not display the existing message, but allows a completely new message to be entered before it is set.

11.20Remote Calling Station Message Mode

11.21Allows the terminal to set a Calling Station Message for a station. The message will be set on

-13-

Page 263
Image 263
Toshiba DK8, DK 16 manual Test Mode Function Diagram, LCD Message Mode, Remote Called Station Message Mode