Table 8: RJ-11 Pinouts for BlueStorm/SP RJ-11 (Ports 7 and 8 Only)

Pin No.

RS-232

Direction

1

DCD

input

2

DSR

input

3

RxD

input

4

RTS

output

5

TxD

output

6

CTS

input

7

DTR

output

8

RI

input

9

SG

signal gnd.

10

N/C

no connect

 

1

2

 

3

4

 

5

6

 

7

8

 

9

10

 

 

P7/P8

Please note that ports 7 and 8 are not accessible through the factory installed bracket.

Table 9: Pinouts and Control Signals for RJ-11 Connectors (BlueStorm/SP RJ-11 Only)

Ports 7 and 8 when a DB-9 cable (part number CAG104K) is attached

DB-9

RS-232

 

Pin No.

Signal

Direction

1

DCD

input

2

RxD

input

3

TxD

output

4

DTR

output

5

SG

signal ground

6

DSR

input

7

RTS

output

8

CTS

input

9

RI

input

 

 

 

Ports 1 through 6, which are accessible through the factory installed bracket

RJ-11

RS-232

 

Pin No.

Signal

Direction

1

RTS

output

2

RxD

input

3

TxD

output

4

DSR

input

5

SG

Signal/power

 

 

ground

6

+12 VDC**

output

 

or +5 VDC**

 

 

 

 

** J1 selects +5 VDC, J2 selects +12 VDC

Male DB-9 Connector

1 5

6 9

RJ-11 Connector

16

Part #:CAG104K

Technical Tip:

Please ensure that you terminate the CTS signal if your application does not use them. The common way to do this is to connect CTS to RTS. Failure to do so may result in loss of a performance on your BlueStorm/SP RJ-11 adapter.

22

Revision 0.10

Image 22
Contents BlueStorm Universal PCI Contact InformationCopyright Notice Limited Lifetime WarrantyTrademark Acknowledgment Table of Contents List of Tables Mail/Courier Customer Support OverviewContact Information Email/InternetFeatures IntroductionFull Duplex Mode BlueStorm Installation OverviewHardware Configuration Half Duplex ModeMulti-drop Slave Mode Jumper Block Diagrams for BlueStormLine Bias/Termination BlueStorm/LP Jumper Block Locations 2 Port Models BlueStorm/SP Jumper Block Locations 8 Port Models Jumper Configuration for BlueStorm BlueStorm/SP RJ-11 8 Port ModelTxD Control DB-25 Male Pinouts for BlueStorm/LP 2 Port Connector Pin Port RS-232 Signal RS-422/485 DirectionHDB-44 Pinouts for BlueStorm/LP 4 Port Connector BlueStorm Installation Guide, Connect Tech Inc VHDCI-68 Female Pinouts for BlueStorm/LP 8 Port Connector VHDCI-68 Female Pinouts for BlueStorm/LP HDB-78 Pinouts for BlueStorm/SP 8 Port Connector Pin Port Signal RS-422/48 232 DirectionHDB-78 Pinouts for BlueStorm/SP Input RxD B+ No connectRJ-45 Pinouts for BlueStorm/SP Opto 4 Port Connector RS-232 RS-422/485 Pin No Signal DirectionPin # RS-232 RS-422/485 DB-9 DB-25 Signal Signal Direction RJ-11 Pinouts for BlueStorm/SP RJ-11 Ports 7 and 8 Only CAG104K Technical TipBlueStorm External I/O Box Diagram RS-422/485 Wiring Diagrams BlueStorm/SP Opto Only Specifications Hardware InstallationSoftware/Driver Installation Baud RatesSurge Suppression UARTsCertification Vcci