Avaya P117F(R) manual Parameter configuration, CR - Refresh The Screen, Reset the Module

Page 19
Parameter configuration

Chapter 3

Configuration

Parameter configuration

The following sections provide step-by-step instructions for configuring each parameter.

In many module configuration menus, the following parameters are displayed:

Display Current Version shows the active configuration.

Display Configured Version shows the new configuration which will take effect after a reset has been made.

Display Default Version shows the system default configuration.

<CR> — Refresh The Screen

Type Enter to clear the screen and re-display the current displayed Menu with the updated parameters.

1 — Reset the Module

If you have changed certain parameters of the P117F(R), the P110 NMA or other switches in the stack, you must reset the agent before you exit the Setup session. The following lists the resets you must initiate and the resets performed automatically by the agent.

Resets the user must initiate

After setting ATM port parameters to their default values

Change in the “Use switch” or any other DIP switch of any other switch

After changing the LSV DIP Switch position

Resets performed automatically by the agent

The first time you set VLANs

Set Ethernet ports’ parameters to their default values

Resetting does not affect any other parameters. You will be asked to confirm the reset before it is executed.

Reset the Agent. *Confirm?* y/[n]:

P117F(R) Stackable Switch Installation Guide

17

Image 19
Contents P117FR AvayaSTACKABLE ETHERNET SWITCH WITH ATM UPLINK Installation GuidePage Preface SAFETY PRECAUTIONSPRECAUTIONS DE SECURITÉ Important Information4. Austauschen einer durchgebrannten Sicherung NUR mit der gleichen Sorte und Belastbarkeit wie sie auf der Sicherheitsaufschrift markiert ist. Die Aufschrift befindet sich neben der Stromzufuhr wo sich auch der Sicherungskasten befindet Chapter OverviewDescription Description ChapterDIP Switches in their Default Positions InstallationSetting the DIP switches Figure 1 The P117FR Stackable Switch Rear Panel Showing theStandalone Operation - Plug ‘n’ Play Installing the P117FR Stackable SwitchStacking Operation Cabling Requirements Exoplane cables. A P110 NMA resides in the uppermost switchP117FR Stackable Switch Installation Guide Rack Mounting Figure 3 P110 rack mounting arrangementFigure 5 The P117FR Front Panel LEDs and Buttons Figure 4 The P117F Front Panel LEDs and ButtonsTable 2 Meaning of the P117F Front Panel Buttons Table 3 Meaning of the P117FR Stackable Switch front panel LEDsMeaning of the additional P117FR front panel LEDs Software Download to the On-Board Agent Connecting the Console TerminalSoftware Download Summary Setup MenusSetup Main Menu Press Enter to view the Setup Main Menu How to Navigate through the Setup menus 1 - Reset the Module Parameter configurationCR - Refresh The Screen 2 - Software Download General The TFTP Process Software Download Procedure3. Type the IP address of the TFTP server and press Enter ping ipaddressofagent Troubleshooting Software Download3 - Agent Access Addresses 6. Type 0 to return to the main menu 4 - IP Routes IP Routes menu Visage 16155R S/W Version Slot # To define an IP Route2. Select Add to define a new IP Route Select Delete to remove an existing IP Route4. Type the Gateway IP address address of the router and press Enter The default community for all three options is public 2. Enter the community name or Enter to leave it unchanged 1. To list permanent managers, select List Listing Permanent Managers2. Press Enter to return to the Permanent Managers Menu Deleting Permanent Managers Adding Permanent ManagersUpdating Permanent Managers Changing the UNI Version 8 5 - UNI VersionChanging the ATM Physical Media 9 6 - ATM Physical Media10 7 - ILMI/ATM Address Changing configured ATM address ILMI11 8 - LECS ATM Address Changing the Configured LECS ATM address12 9 - ELAN Configuration Display ELAN/VLAN associations Changing the Default ELAN Name Displaying Default ELAN information13 10 - ATM Redundancy 15 12 - Set Ethernet Port Parameters to their default values 14 11 - Set ATM Port Parameters to their Default ValuesP117FR Stackable Switch Installation Guide Figure 6 Terminal port - RS-232 Wiring Connection to Console Terminal Terminal Connector Pin AssignmentsDocument number 130001 Rev. A 2003 Avaya Inc. All rights reserved