Appendix 2: Troubleshooting
Q1. I Can not login to the Web interface of ZSR4154WE after entering the IP address in the address field?
Step 1: check ZSR4154WE if it works well. Once the device is powered on for a few seconds, the SYS indicator on the panel will be turned on. If it is not, please contact us.
Step 2: check the network cable if it is work and the corresponding indicator is “Always ON”. Sometimes, the indicator is “Always ON”, but it does not mean it gets through.
Step 3: Run “Ping” command and check if it can ping ZSR4154WE’s LAN IP address 192.168.0.1. If it is OK, please make sure your browser does not access the Internet by proxy server. If the ping fails, you can press the “RESET” button for 7 seconds to restore to default settings. And then repeat the ping operation. If it still does not work, please contact us.
Q2. I forget the login password and can not enter the setting page. What can I do?
Press the “RESET” button for 7 seconds to restore ZSR4154WE to default settings.
Q3. The computer connected with ZSR4154WE shows IP address conflict. What can I do?
Check if there are other DHCP servers in the LAN. If there have, disable them. The default IP address of ZSR4154WE is 192.168.0.1 and please maker sure the address is not occupied by other devices. If there are two computers with the same IP addresses, please modify one.
Q4. I can not use
It happens in ADSL connection and Dynamic IP users. And you need modify the default MTU value (1492). Please in the “WAN Setting” modify the MTU value with the recommended value as 1450 or 1400.
48