Zhone Technologies installation instructions Model 5620 RTU Technical Specifications

Page 16

HThe DSL interface connector uses a 6-pin, non-keyed modular plug.

RJ11 6-Pin Connector

Pin # Function

1 & 2 Not used

3DSL Ring

4DSL Tip 5 & 6 Not used

DSL

Cable

6-Pin

RJ11 Plug

Pin #6

Pin #1

98-15304-01

Model 5620 RTU Technical Specifications

Item

Specification*

Height x Width x Depth

1.43x 6.00x 8.75(3.64 cm x 15.24 cm x 22.23 cm)

 

 

 

Weight

1 lb. 1 oz.

(0.48 kg)

 

 

 

Power

Input:

100 Vac (+10%), 50 Hz;

Class 2 Transformer normal

 

120 Vac (+10%), 60 Hz; or

 

230 Vac (+10%), 50/60 Hz

service input voltage range

 

Output:

15 Vdc nominal, minimum 0.6A

 

 

 

 

Approvals

 

 

FCC Part 15

Class B Subpart B digital device

CISPR 22

Class B

 

Safety Certifications

Refer to equipment's label for approvals on product

 

 

 

Physical Environment

 

 

Operating temperature

32°F to 104°F (0°C to 40°C)

Storage temperature

±4°F to 158°F (±20°C to 70°C)

Relative humidity

5% to 95% (noncondensing)

Shock and vibration

Withstands normal shipping and handling

 

 

Heat Dissipation

33.8 Btu/hr. (max.) at nominal input voltage

 

 

 

Interface Connectors

 

 

DSL Interface

RJ11 6-pin

 

Ethernet Type II Frame

10BaseT 8-pin

 

 

 

* Technical Specifications subject to change without notification.

16

Image 16
Contents Before You Begin Wiring and Cables NeededDocument Number Document Title Package Checklist What Does the Hotwire Radsl RTU Do?DSL Access with a Hotwire 5030 or 5038 Pots Splitter Network Service Provider DSL Access with a Hotwire 5038 Distributed Pots SplitterCustomer Premises CP DSL Access without a Pots Splitter DSL RTUProcedure Installing the DSL Access WiringPunchdown Block Telephone Network Interface Device NID DSL/POTSPOTS/DSL RJ11 Wall JackHotwire RTU Installing the Hotwire 5620 RTUPots Splitter Ethernet Line Ferrite Optional RTU Wall Placement RTU Hardware Template Power-On Alarm redStatus LEDs Condition StatusTroubleshooting LED Symptom ActionIncreasing the Number of End-User Systems NSPCables & Connectors Pin # FunctionModel 5620 RTU Technical Specifications SpecificationImportant Safety Instructions Declaration of Conformity Canada EMI Warnings Trademarks Warranty, Sales, and Service InformationDocument Feedback