Blade ICE BMD00098 New and Updated Features, Remote Monitoring, Link Layer Detection Protocol

Page 10

BLADE OS 5.1 Release Notes

New and Updated Features

BLADEOS 5.1 for 1/10Gb Uplink Ethernet Switch Module (GbESM) has been updated to include new and enhanced features in support of server and peer switch discovery, as well as failure detection at the link layer. In addition, there are enhancements to existing implementations in the areas of dynamic routing protocols, configuration and reporting.

The list of features below summarizes the updated features. For more detailed information about configuring GbESM features and capabilities, refer to the complete BLADEOS 5.1 documentation as listed on page 3.

Remote Monitoring

BLADEOS 5.1 now supports Remote Monitoring (RMON).

RMON allows network devices to exchange network monitoring data, gather cumulative and history statistics for Ethernet interfaces, and create and trigger alarms for user-defined events.

An RMON management application can be used to access RMON MIB information on the GbESM, as described in RFC 1757. The switch supports RMON Group 1 (Statistics), Group 2 (History), Group 3 (Alarms), and Group 9 (Events).

RMON properties are configured globally in the RMON menu, and enabled on a per-port basis in the Port menu:

# /cfg/rmon

(global RMON menu)

-and-

 

# /cfg/port <x>/rmon

(per-port RMON menu)

 

 

Link Layer Detection Protocol

BLADEOS 5.1 now supports 802.1AB Link Layer Detection Protocol (LLDP). Using LLDP, the GbESM advertises port and link information to other LLDP-capable devices and accepts their LLDP advertisements for the purpose of discovering pertinent information about remote ports.

Switch port information and any remote device information is stored in a Managed Information Base (MIB). Higher-layer management tools may access the MIB to accumulate and report such information, and even to and discover configuration inconsistencies between systems on the same IEEE 802 LAN.

The LLDP configuration menu is accessed using the following CLI command:

#/cfg/l2/lldp

10

BMD00098, December 2009

Image 10
Contents Release Notes Blade OS 5.1 Release Notes Release Notes Hardware Support 10Gb Uplink ESM FaceplateRecommended SFP+ transceiver Updating the Switch Software Image Loading New Software to Your SwitchUsing the Bladeos CLI Using the Iscli Using the BBI Remote Monitoring New and Updated FeaturesLink Layer Detection Protocol Uni-Directional Link Discovery Protocol Operation/Administration/Maintenance ProtocolSFlow Monitoring Internal Loopback Interface Rate LimitingHot Links Ospf EnhancementsACL Precedence Enhancement Lacp Trunk EnhancementsLayer 2 Failover Enhancements Forwarding Database EnhancementsSTP Fast Uplink Bridge Priority ISL Layer 2 Protocol EnhancementsCLI List and Range Inputs Chassis Internal Network BC-S Chassis SupportINT1 Other Features Supplemental Information Management ModuleManagement Module/GbESM Connectivity Secure Management Network Trunk Group Configuration TipsSecure Shell SSH Internal Port Autonegotiation Spanning Tree Configuration TipsSyslog Configuration Tip FTP/TFTP Directory PathIgmp Relay Known issuesAccess Control Lists Interoperability with Older HubsStatic Mrouter Link Aggregation Control ProtocolLinking at 10/100Mb QoS MeteringTrunk and Link Loop Radius with SSHv2RIP MIBs Trunk TrafficStrong Password Expiration