Blade ICE BMD00098 manual Uni-Directional Link Discovery Protocol, SFlow Monitoring

Page 11

BLADE OS 5.1 Release Notes

Uni-Directional Link Discovery Protocol

BLADEOS 5.1 now supports the Uni-Directional Link Discovery (UDLD) protocol, compliant with RFC 5171. UDLD operates at Layer 2 in conjunction with existing IEEE 802.3 Layer 1 fault detection mechanisms. It is used between peer devices to detect and disable unidirectional Ethernet links caused, for instance, by mis-wired cable strands, interface malfunctions, or media converter faults.

UDLD is configured on a per-port basis. It is disabled by default. The UDLD configuration menu is available using the following CLI command:

#/cfg/port <x>/udld

Operation/Administration/Maintenance Protocol

BLADEOS 5.1 now supports IEEE 802.3ah Operation, Administration, and Maintenance (OAM) protocol. OAM allows the switch to detect faults on physical port links. Using OAM, if the Local Information that a port sends does not match the Remote Information received, the link is determined to be in an anomalous condition and is automatically disabled.

OAM is configured on a per-port basis. It is disabled by default. The OAM configuration menu is available using the following CLI command:

#/cfg/port <x>/oam

sFlow Monitoring

BLADEOS 5.1 now supports sFlow technology for monitoring traffic in data networks. The switch software includes an embedded sFlow agent which can be configured on a per-port basis to sample network traffic and provide continuous statistical report information to a central sFlow analyzer.

sFlow features are disabled by default, but may be configured using the following menu:

#/cfg/sys/sflow

BMD00098, December 2009

11

Image 11
Contents Release Notes Blade OS 5.1 Release Notes Release Notes 10Gb Uplink ESM Faceplate Hardware SupportRecommended SFP+ transceiver Loading New Software to Your Switch Updating the Switch Software ImageUsing the Bladeos CLI Using the Iscli Using the BBI Link Layer Detection Protocol New and Updated FeaturesRemote Monitoring SFlow Monitoring Operation/Administration/Maintenance ProtocolUni-Directional Link Discovery Protocol Rate Limiting Internal Loopback InterfaceOspf Enhancements Hot LinksForwarding Database Enhancements Lacp Trunk EnhancementsLayer 2 Failover Enhancements ACL Precedence EnhancementCLI List and Range Inputs ISL Layer 2 Protocol EnhancementsSTP Fast Uplink Bridge Priority BC-S Chassis Support Chassis Internal NetworkINT1 Other Features Management Module Supplemental InformationManagement Module/GbESM Connectivity Secure Shell SSH Trunk Group Configuration TipsSecure Management Network FTP/TFTP Directory Path Spanning Tree Configuration TipsSyslog Configuration Tip Internal Port AutonegotiationInteroperability with Older Hubs Known issuesAccess Control Lists Igmp RelayQoS Metering Link Aggregation Control ProtocolLinking at 10/100Mb Static MrouterTrunk Traffic Radius with SSHv2RIP MIBs Trunk and Link LoopStrong Password Expiration