Blade ICE BMD00098 manual Known issues, Access Control Lists, Igmp Relay

Page 23

BLADE OS 5.1 Release Notes

Known issues

The following are known issues for BLADEOS 5.1 on the 1/10Gb Uplink Ethernet Switch Module.

Access Control Lists

￿When an Access Control List (ACL) is installed on two different ports, only one statistics counter will be available. The GbESM does not support two different statistics counter for one ACL installed on two different ports.

￿The ACL filters for TCP/UDP work properly only on packets that do not have IP options.

￿When configuring an ACL to set 802.1p priority for in-profile packets, and updating the DSCP field using TOS bits for out-of-profile packets, the out-of-profile packets will have also the 802.1p priority set as defined in the in-profile setting.

￿Although the management port can be configured for port filtering option, actual port filtering will not occur, because the system filters out the management VLAN.

IGMP Relay

￿When having joins from multiple VLANs, and the multicast data transmitter is on a VLAN that did not receive any joins, multicast data is routed only if the flood option is disabled using the

/cfg/l3/igmp/adv/flood d command.

￿If an IGMP v2 joins an IGMP group on the same port where an IGMP v1 join has already been issued, the software will default to the IGMP v1 timeout value.

Interoperability with Older Hubs

The command-line interface might display link up and link down messages continuously for an external port that is connected to certain older hub models configured for 100 Mbps halfduplex. The display might show link up erroneously. This behavior has been observed when connecting the GbESM with the following devices:

￿NETGEAR FE104 100 hub

￿SBS 1000Base-T NIC

￿3Com Linkbuilder FMS100 Hub 3C250 TX/I

￿3Com SuperStack II 100TX 3C250C-TX-24/12

￿Nortel Baystack 204 Hub

If the GbESM is connected to an Alteon Application Switch which requires a link speed of 100 Mbps half-duplex, then enable auto negotiation on the GbESM port with port speed=any, mode=any, fctl=both, and auto=on.

BMD00098, December 2009

23

Image 23
Contents Release Notes Blade OS 5.1 Release Notes Release Notes 10Gb Uplink ESM Faceplate Hardware SupportRecommended SFP+ transceiver Loading New Software to Your Switch Updating the Switch Software ImageUsing the Bladeos CLI Using the Iscli Using the BBI Link Layer Detection Protocol New and Updated FeaturesRemote Monitoring SFlow Monitoring Operation/Administration/Maintenance ProtocolUni-Directional Link Discovery Protocol Rate Limiting Internal Loopback InterfaceOspf Enhancements Hot LinksForwarding Database Enhancements Lacp Trunk EnhancementsLayer 2 Failover Enhancements ACL Precedence EnhancementCLI List and Range Inputs ISL Layer 2 Protocol EnhancementsSTP Fast Uplink Bridge Priority BC-S Chassis Support Chassis Internal NetworkINT1 Other Features Management Module Supplemental InformationManagement Module/GbESM Connectivity Secure Shell SSH Trunk Group Configuration TipsSecure Management Network FTP/TFTP Directory Path Spanning Tree Configuration TipsSyslog Configuration Tip Internal Port AutonegotiationInteroperability with Older Hubs Known issuesAccess Control Lists Igmp RelayQoS Metering Link Aggregation Control ProtocolLinking at 10/100Mb Static MrouterTrunk Traffic Radius with SSHv2RIP MIBs Trunk and Link LoopStrong Password Expiration