Blade ICE BMD00098 manual Spanning Tree Configuration Tips, Syslog Configuration Tip

Page 22

BLADE OS 5.1 Release Notes

Spanning Tree Configuration Tips

To ensure proper operation with switches that use Cisco Per VLAN Spanning Tree (PVST+), you must do one of the following:

￿Create a separate Spanning Tree Group for each VLAN.

￿Manually add all associated VLANs into a single Spanning Tree Group.

When using Layer 2 Trunk Failover, disable Spanning Tree Protocol on external ports.

Syslog Configuration Tip

The facility parameter traditionally is used to correlate services (such as IP, CLI, etc.) to messages. This is done to distinguish between the different services that are running in the network/device. However, for the GbESM, there is a single configured facility value (0-7) used on all messages. By configuring a unique facility value for each switch, a single SYSLOG server can distinguish between the various GbESMs in the network. Refer to “System Host Log Configuration” in the BLADEOS 5.1 Command Reference.

Internal Port Autonegotiation

By default, link autonegotiation is turned on for internal ports. This is in contrast to external ports, where autonegotiation is off by default. Internal ports use autonegotiation in order to support the Wake-Over-LAN (WOL) features of some servers. If an attached server does not support autonegotiation or WOL, turn autonegotiation off for the internal port.

FTP/TFTP Directory Path

When you use the CLI to perform a FTP/TFTP file transfer, you cannot use a forward slash ( / ) in the directory path, unless it is preceded by a back slash ( \ ). This issue occurs only when a full command is issued on one line.

For example, the following is invalid:

#/boot/gtimg 1 10.10.10.2 image_directory/filename

The following is correct:

# /boot/gtimg 1 10.10.10.2 image_directory\/filename

22

BMD00098, December 2009

Image 22
Contents Release Notes Blade OS 5.1 Release Notes Release Notes Hardware Support 10Gb Uplink ESM FaceplateRecommended SFP+ transceiver Updating the Switch Software Image Loading New Software to Your SwitchUsing the Bladeos CLI Using the Iscli Using the BBI Remote Monitoring New and Updated FeaturesLink Layer Detection Protocol Uni-Directional Link Discovery Protocol Operation/Administration/Maintenance ProtocolSFlow Monitoring Internal Loopback Interface Rate LimitingHot Links Ospf EnhancementsACL Precedence Enhancement Lacp Trunk EnhancementsLayer 2 Failover Enhancements Forwarding Database EnhancementsSTP Fast Uplink Bridge Priority ISL Layer 2 Protocol EnhancementsCLI List and Range Inputs Chassis Internal Network BC-S Chassis SupportINT1 Other Features Supplemental Information Management ModuleManagement Module/GbESM Connectivity Secure Management Network Trunk Group Configuration TipsSecure Shell SSH Internal Port Autonegotiation Spanning Tree Configuration TipsSyslog Configuration Tip FTP/TFTP Directory PathIgmp Relay Known issuesAccess Control Lists Interoperability with Older HubsStatic Mrouter Link Aggregation Control ProtocolLinking at 10/100Mb QoS MeteringTrunk and Link Loop Radius with SSHv2RIP MIBs Trunk TrafficStrong Password Expiration