Blade ICE BMD00098 manual INT1

Page 17

BLADE OS 5.1 Release Notes

￿Port link information (/info/link) for switches installed in bay 3 and bay 4:

Alias

Port

Speed

Duplex

Flow Ctrl

Link

----

-----

-----

-------- --TX-----RX--

------

INT1

1

1000

full

yes

yes

up

INT2

2

1000

full

yes

yes

up

INT3

3

1000

full

yes

yes

down

INT4

4

1000

full

yes

yes

up

INT5

5

1000

full

yes

yes

up

INT6

6

1000

full

yes

yes

up

MGT1

15

100

full

yes

yes

up

EXT1

17

10000

any

yes

yes

up

EXT2

18

10000

any

yes

yes

up

...

 

 

 

 

 

 

 

 

 

 

 

 

 

￿Port information (/info/port) for switches installed in bay 1 and bay 2:

Alias Port Tag Fast Lrn Fld PVID

NAME

 

VLAN(s)

----- ---- --- ---- --- --- ----

--------------

--------------------

INT1A

1

y

n

e

e

1

INT1A

1

4095

INT1B

2

y

n

e

e

1

INT1B

1

4095

INT2A

3

y

n

e

e

1

INT2A

1

4095

INT2B

4

y

n

e

e

1

INT2B

1

4095

INT3A

5

y

n

e

e

1

INT3A

1

4095

INT3B

6

y

n

e

e

1

INT3B

1

4095

INT4A

7

y

n

e

e

1

INT4A

1

4095

INT4B

8

y

n

e

e

1

INT4B

1

4095

INT5A

9

y

n

e

e

1

INT5A

1

4095

INT5B

10

y

n

e

e

1

INT5B

1

4095

INT6A

11

y

n

e

e

1

INT6A

1

4095

INT6B

12

y

n

e

e

1

INT6B

1

4095

SMGT1

13

y

n

e

e

1

SMGT1

1

4095

SMGT2

14

y

n

e

e

1

SMGT2

1

4095

MGT1

15

y

n

e

e

4095*MGT1

4095

EXT1

17

n

n

e

e

1

EXT1

1

 

EXT2

18

n

n

e

e

1

EXT2

1

 

EXT3

19

n

n

e

e

1

EXT3

1

 

EXT4

20

n

n

e

e

1

EXT4

1

 

EXT5

21

n

n

e

e

1

EXT5

1

 

EXT6

22

n

n

e

e

1

EXT6

1

 

EXT7

23

n

n

e

e

1

EXT7

1

 

EXT8

24

n

n

e

e

1

EXT8

1

 

EXT9

25

n

n

e

e

1

EXT9

1

 

 

 

 

 

 

 

 

 

 

 

BMD00098, December 2009

17

Image 17
Contents Release Notes Blade OS 5.1 Release Notes Release Notes 10Gb Uplink ESM Faceplate Hardware SupportRecommended SFP+ transceiver Loading New Software to Your Switch Updating the Switch Software ImageUsing the Bladeos CLI Using the Iscli Using the BBI Link Layer Detection Protocol New and Updated FeaturesRemote Monitoring SFlow Monitoring Operation/Administration/Maintenance ProtocolUni-Directional Link Discovery Protocol Rate Limiting Internal Loopback InterfaceOspf Enhancements Hot LinksLayer 2 Failover Enhancements Lacp Trunk EnhancementsACL Precedence Enhancement Forwarding Database EnhancementsCLI List and Range Inputs ISL Layer 2 Protocol EnhancementsSTP Fast Uplink Bridge Priority BC-S Chassis Support Chassis Internal NetworkINT1 Other Features Management Module Supplemental InformationManagement Module/GbESM Connectivity Secure Shell SSH Trunk Group Configuration TipsSecure Management Network Syslog Configuration Tip Spanning Tree Configuration TipsInternal Port Autonegotiation FTP/TFTP Directory PathAccess Control Lists Known issuesIgmp Relay Interoperability with Older HubsLinking at 10/100Mb Link Aggregation Control ProtocolStatic Mrouter QoS MeteringRIP MIBs Radius with SSHv2Trunk and Link Loop Trunk TrafficStrong Password Expiration