Blade ICE BMD00098 manual Chassis Internal Network, BC-S Chassis Support

Page 16

BLADE OS 5.1 Release Notes

Chassis Internal Network

BLADEOS 5.1 now supports BladeCenter Chassis Internal Network (CIN). CIN provides internal connectivity between blade server ports and the internal Advanced Management Module (AMM) port. This allows blade server users to access the AMM via CLI, web-browser, or SNMP session, and allows the AMM to use services on the blades, such as LDAP, SMTP, DNS, and NTP.

BC-S Chassis Support

BLADEOS 5.1 supports the BladeCenter BC-S chassis. When the GbESM is installed in the BC-S chassis, the following information displays reflect the BC-S port mapping:

￿Port link information (/info/link) for switches installed in bay 1 and bay 2:

Alias

Port

Speed

Duplex

Flow Ctrl

Link

----

-----

-----

-------- --TX-----RX--

------

INT1A

1

1000

full

yes

yes

up

INT1B

2

1000

full

yes

yes

up

INT2A

3

1000

full

yes

yes

up

INT2B

4

1000

full

yes

yes

up

INT3A

5

1000

full

yes

yes

down

INT3B

6

1000

full

yes

yes

up

INT4A

7

1000

full

yes

yes

up

INT4B

8

1000

full

yes

yes

up

INT5A

9

1000

full

yes

yes

up

INT5B

10

1000

full

yes

yes

up

INT6A

11

1000

full

yes

yes

up

INT6B

12

1000

full

yes

yes

up

SMGT1

13

1000

full

yes

yes

up

SMGT2

14

1000

full

yes

yes

up

MGT1

15

100

full

yes

yes

up

EXT1

17

10000

any

yes

yes

up

EXT2

18

10000

any

yes

yes

up

EXT3

19

10000

any

yes

yes

up

EXT4

20

1000

any

yes

yes

up

EXT5

21

1000

any

yes

yes

up

EXT6

22

1000

any

yes

yes

up

EXT7

23

1000

any

yes

yes

up

EXT8

24

1000

any

yes

yes

up

EXT9

25

1000

any

yes

yes

up

 

 

 

 

 

 

 

16

BMD00098, December 2009

Image 16
Contents Release Notes Blade OS 5.1 Release Notes Release Notes Hardware Support 10Gb Uplink ESM FaceplateRecommended SFP+ transceiver Updating the Switch Software Image Loading New Software to Your SwitchUsing the Bladeos CLI Using the Iscli Using the BBI Remote Monitoring New and Updated FeaturesLink Layer Detection Protocol Uni-Directional Link Discovery Protocol Operation/Administration/Maintenance ProtocolSFlow Monitoring Internal Loopback Interface Rate LimitingHot Links Ospf EnhancementsLacp Trunk Enhancements Layer 2 Failover EnhancementsACL Precedence Enhancement Forwarding Database EnhancementsSTP Fast Uplink Bridge Priority ISL Layer 2 Protocol EnhancementsCLI List and Range Inputs Chassis Internal Network BC-S Chassis SupportINT1 Other Features Supplemental Information Management ModuleManagement Module/GbESM Connectivity Secure Management Network Trunk Group Configuration TipsSecure Shell SSH Spanning Tree Configuration Tips Syslog Configuration TipInternal Port Autonegotiation FTP/TFTP Directory PathKnown issues Access Control ListsIgmp Relay Interoperability with Older HubsLink Aggregation Control Protocol Linking at 10/100MbStatic Mrouter QoS MeteringRadius with SSHv2 RIP MIBsTrunk and Link Loop Trunk TrafficStrong Password Expiration