Multitech MT5600ZDXV manual Registers, Register Unit Range Default Description

Page 53

User Guide

S-Registers

Certain Command Mode configurations are stored in memory registers called, S-Registers. The S command is used to assign a value to, and to read the current value of an S-Register. To assign a value to an S-Register, enter the letter S, followed by the S-Register number and an equals sign (=). To read an S-Register value, enter the letter S followed by the S-Register number and a question mark (?), then hit RETURN. To verify that the S- Register value was entered correctly, enter for example, ATS8? and hit RETURN. You should receive a response of the assigned value given to that S-Register.

Register

Unit

Range

Default

Description

S0

rings

0, 1–255 1

Sets the number of rings before

 

 

 

 

the modem answers. ATS0=0

 

 

 

 

disables auto-answer complete-

 

 

 

 

ly.

S1

rings

0–255

0

Counts the number of rings that

 

 

 

 

have occurred.

S2

decimal

0–255

43 (+)

Sets ASCII code for the escape

 

 

 

 

character. Values greater than

 

 

 

 

127 disable the escape sequence.

S3

decimal

0–127

13 (^M) Sets ASCII code for the carriage

 

 

 

 

return character.

S4

decimal

0–127

10 (^J)

Sets ASCII code for the line feed

 

 

 

 

character.

S5

decimal

0–255

8 (^H)

Sets ASCII code for the back-

 

 

 

 

space character. Values greater

 

 

 

 

than 32 disable the backspace

 

 

 

 

character.

53

Image 53
Contents Page Models MT5600ZDX & Zdxv User Guide Chapter Chapter Page Introduction Introduction Product Description Data Fax What Is in Your Modem Package?Software Considerations for Zdxv Voice Zdxv onlyInstallation How to Use This ManualAT Commands, S-Registers & Result Codes TroubleshootingInstallation Serial Cable ComputerTelephone Line Safety Warning TelecomCommunications Software Assemble the ModemPhone Line Installation ProcessUser Guide 2a. Modem Connections Sound Card Considerations Zdxv onlySoundCard Connections Zdxv only Modem Front Panel LED IndicatorsUser Guide Operating Your Modem Is Your Modem Ready for Use?Simple Operations Software ConfigurationHardware/Software Confirmation Modem Initialization SetupNone of the LEDs Light When the Modem Is On Modem Does Not Respond to Commands Modem Dials But Cannot Make a Connection Models MT5600ZDX & Zdxv Modem Disconnects While Online Slow File Transfer Modem Cannot Connect When AnsweringGarbage Characters on the Monitor Losing DataPage AT Commands Registers Result Codes AT Commands Command Ds Dial Zdxv only Command En Echo Command Mode Characters Command DS=n Dial Stored Telephone NumberCommand Hn On-Hook/Off-Hook Control Command Information RequestCommand Nn Modulation Handshake Command Mn Monitor Speaker ModeCommand On Return Online to Data Mode Command Qn Enable/Disable Result CodesCommand Wn Connect Message Control Command Sn Read/Write Register ValueCommand Vn Terse/Verbose Result Code Format Command Yn Long Space Disconnect Command Xn Result Code SelectionCommand Zn Modem Reset Command &Cn Data Carrier Detect DCD ControlCommand &Fn Load Factory Default Settings Command &Dn Data Terminal Ready DTR ControlCommand &Jn Telephone Jack Control Command &Gn 22bis Guard Tone ControlCommand &Kn Flow Control Selection Command &Ln Leased Line OperationCommand Asynchronous Communications Mode Command &Mn Communications ModeCommand Data Set Ready DSR Control Command $SBn Serial Baud RateCommand V1 Display Last Connection Statistics Command &V0 View Current ConfigurationCommand &Zn=x Store Telephone Number Command &Wn Store Current ConfigurationCommand %L Line Signal Level Command %Q Line Signal QualityCommand %8 Plug and Play Vendor ID and Product Number Command %7 Plug and Play Serial NumberCommand %C Enable/Disable Data Compression Command \An Select Maximum Block SizeCommand \Kn Set Break Control Command \Bn Transmit Break to RemoteCommand \Vn Single Line Connect Message Command \Nn Error Correction Mode SelectionCommand +MS Select Modulation +MS=mod,automode,minrate,maxrate,xlaw ,rbsignallingcrCommand Mn Command SDR=n Enable/Disable Distinctive RingCommand -Kn MNP 10 MNP Extended Services Command *Hn MNP 10 Link Negotiation SpeedCommand -Qn MNP 10 Enable Fallback to V.22 bis/V.22 Command SEC=n Enable/Disable MNP10-ECCommand *D View Delayed Numbers Command En MNP 10 Compromise Equalizer Enable CommandCommand *B View Numbers in Blacklist Command P Pulse Dial Command #CID Caller IDCommand T Tone Dial Command +++ Escape SequenceRegisters Register Unit Range Default DescriptionS11 S10S12 S18S24 S29 S25S30 S32S37 Bit-Mapped Options Status Register Unit Range Default Description S38 S48 Register Unit Range Default Description S46S91 S82 Break Handling OptionsS95 Extended Result Codes S92Verbose Description Result CodesResult Codes Delayed Connect Troubleshooting Local Analog Loopback Test Local Analog Loopback Test/V.54 LoopDigital Loopback Test/V.54 Loop 2 Local/Manual Digital Loopback Test Local/manual Digital Loopback Test/V.54 Loop 2 Remote/ AutomaticDigital Loopback Test remote/automatic Page Warranty Service Tech Support Online Warranty Registration Limited WarrantyRecording Modem Information ServiceTech Support Mail About Ordering AccessoriesPhone FaxIf you know the file name About the Multi-Tech BBSLogging on to the Multi-Tech BBS Leaving a Message If you don’t know the file nameReading a Message Bulletins Using Flash to Upgrade Modem FirmwareFlash Procedure Models MT5600ZDX & Zdxv About Internet Tech Support Page Technical Specifications Carrier Frequencies 1800 Hz Command Buffer 40 charactersData Carrier Frequencies Transmit Originate300 bps 22bis/V.22 orBell Standard Carrier Frequencies Fax 21 CH2Indicators Connectors DiagnosticsTemperature Power Requirement Power ConsumptionRegulatory Information Models MT5600ZDX & Zdxv User Guide Canadian Limitations Notice FCC Fax UpdateUser Guide Compliance with Babt Requirements International Modem RestrictionsUser Guide Compliance with BS6789 .1 and Part Compliance with BS6328 Part Modem CE Mark EMC and Safety ComplianceNew Zealand Telecom Warning Notice Commission Decision CTR21 & European Directive NoticeInformation Support Appendix C V.90 InformationUser Guide Models MT5600ZDX & Zdxv

MT5600ZDXV, MT5600ZDX specifications

The MultiTech MT5600ZDX and MT5600ZDXV are state-of-the-art modems designed to offer reliable communication capabilities for a variety of applications. These devices are particularly favored in industrial, telecommunications, and enterprise settings due to their robust performance and versatility.

One of the standout features of the MT5600ZDX series is its ability to support both analog and digital signaling. This dual compatibility enables seamless integration with existing telecommunication infrastructure, making it an ideal choice for businesses looking to upgrade without overhauling their entire system. With ITU-T V.34 modem technology, these devices support high-speed data transmission rates of up to 56 kbps, ensuring quick and efficient data transfer.

The MT5600ZDX and MT5600ZDXV models come equipped with a comprehensive array of communication protocols, including PPP, TCP/IP, and the unique Multitech proprietary protocols. This broad compatibility allows for easy connection to various networks and devices, facilitating smooth data exchange across platforms.

Another notable feature is the built-in error correction and data compression capabilities. With technologies such as MNP, V.42, and V.42bis, users can expect enhanced data integrity and faster transmission speeds, which are particularly crucial in environments with high noise levels or signal interference. These features make the modems highly effective for remote monitoring applications, telemetry, and point-of-sale terminals.

Additionally, both models excel in terms of connectivity options. The MT5600ZDX includes a standard RS-232 interface, while the MT5600ZDXV offers an enhanced V.24 interface for those requiring additional communication flexibility. This variety in connectivity options ensures that users can integrate these devices into a wide range of systems, whether for industrial automation or remote data acquisition.

Durability and reliability are also core characteristics of the MT5600ZDX series. Designed to operate in challenging environments, they boast a wide operating temperature range and robust casing, making them suitable for deployment in harsh industrial conditions.

In conclusion, the MultiTech MT5600ZDX and MT5600ZDXV modems provide a feature-rich solution for organizations seeking high-performance communication. With advanced technologies, exceptional versatility in connections, and reliability in demanding settings, they continue to stand out as preferred choices for efficient industrial communication solutions. These devices not only enhance operational efficiency but also pave the way for future-proof connectivity in an increasingly digital world.