RAD Data comm operation manual Functional Description, ASM-60 Block Diagram

Page 12

Chapter 1 Introduction

ASM-60Installation and Operation Manual

 

 

 

 

 

 

 

 

 

1.3 Functional Description

This section provides a functional description (Figure 1-3) of ASM-60 in the form of block diagrams.

A11-A15

CPU

 

RS-232

Additional

A0-A7, A14

Decoder

 

D8-D15

Latch/Buffer

LEDsControl

TxD, RxD

DTE Interface

INT, EXT

Clock

Data,

 

 

 

Clock

EVM1

HYBRID1

TRANSF.1

 

VDSL

 

VDSL

Line A

 

 

Framer

 

Line Interface

Data,

 

 

Line B

 

 

 

Clock

EVM2

HYBRID2

TRANSF.2

 

3.3V

 

 

AC

 

Power

5.0V

Supply

 

 

 

Figure 1-3. ASM-60 Block Diagram

The ASM-60 modem consists of the following major modules:

CPU and Peripherals – This module, based on a microprocessor, includes Flash (1 Mb), RAM (0.5 Mb) and EEPROM (8 kb) memory and controls the ASM-60 operation.

VDSL Framer – This module encapsulates data bit stream coming from DTE and transmits it over two different analog lines. At the other end, it reverses the process by converting the two line data into one bit stream for the DTE. In addition, the VDSL framer supplies clock to the DTE.

VDSL Line Interface – Consists of two identical DSP modules. Each module transmits and receives signals over 2-wire at half of the data rate that running into the DTE interface.

1-4

Functional Description

Image 12
Contents ASM-60 International Headquarters RAD Data Communications IncPage Warranty Safety Warnings Ports Safety StatusInstalling ASM-60 Setting the Internal SwitchesConnecting the Interfaces Connecting the PowerConfiguring ASM-60 Operating ASM-60Normal Indications Selecting the Data RateContents List of Figures Chapter Introduction OverviewReal Time Alarms DTE InterfaceManagement Test CapabilitiesPhysical Description D View of ASM-60ASM-60 Block Diagram Functional DescriptionTechnical Specifications Support via RJ-45 connectorIR-IP IP router via RJ-45 connector Interface 24/RS-232 TypeTransformers to the transmit and receive lines Fuse 250A, slow-blowChapter Installation and Setup Site Requirements and PrerequisitesPackage Contents Installation and SetupPerforming the Internal Settings To install ASM-60Connecting the Line Opening the ASM-60 CaseClosing the ASM-60 Case Connecting the DTE Hssi Interface Connector PinoutTo connect the Hssi interface To connect the AC power Installation and Setup Front Panel Indicators ASM-60 LED IndicatorsChapter Operation Name FunctionASM-60 Indicator Status Turning On ASM-60Turning Off ASM-60 Control Port Interface Characteristics Chapter Management from a TerminalPreparing for the Control Session Preparing TerminalNavigating the Management Menus Initiating a Control SessionTo initiate a control session To choose an optionStarting the Control Session Terminal Management MenusTo display the Configuration menu Main MenuTo access the Display menu Displaying the ASM-60 System InformationDisplaying the ASM-60 Status To display the ASM-60 statusResetting ASM-60 To reset ASM-60Resetting ASM-60 Chapter Diagnostics Error DetectionPower-Up Self-Test AlarmsTo access the log file Working with the Log FileDisplaying the Vdsl Performance Diagnostics ASM-60 AlarmsTo display the Vdsl diagnostics Number Terminal Message Description SeverityAfter the ASM-60 power-up ASM-60 Performance Monitoring ParametersRunning the Diagnostic Tests Running the LEDs TestTo run the LEDs test Running the Diagnostic Tests IR-ETH Connector Options Appendix a IR-ETH Interface ModuleLAN ProtocolInstallation and Operation Figure A-4. IR-ETH Layout UTP OptionDIP Switch Settings LED IndicatorsConnecting to LAN Table A-2. DIP Switch SettingsIR-ETH/QH Connector Appendix B IR-ETH/QH Interface ModuleIntroduction Table B-1 RJ-45 Connector Pinout Pin Signal FunctionProtocol Point-to-point Data Rate Kbps to 45 Mbps Setting the DIP Switch Table B-2. DIP Switch SettingsSection Name Description Possible Settings Factory Setting Connecting the LAN Table B-3. IR-ETH/QH LED IndicatorsLED Name Color Description Location Appendix C IR-IP Interface Module OverviewDelay Frame Connector 10BaseT UTP Shielded RJ-45Standard Conforms to Ieee 802.3/Ethernet Data Rate TopologyIR-IP DIP Switch IR-IP LEDsTable C-1. IR-IP LEDs Functions Table C-3 RJ-45 PinoutAccessing the IR-IP Management Subsystem IR-IP Management Subsystem, GeneralIntroduction Performing Preliminary Configuration Default IP Communication ParametersOutline of Preliminary Configuration To perform the preliminary configuration procedureConnecting the Telnet Host Preliminary Telnet Host ConfigurationAssigning the Router LAN Interface Address IP Learning MechanismTo view and edit the ARP table contents To configure the IP router LAN addressAssigning a LAN IP Address to a New IR-IP Changing the LAN IP Address of a Configured IR-IP What to Do IfNo ping replies from IR-IP IP learning process is not successfulGeneral Operating Procedures IR-IP Management UtilityStarting a Management Utility Quick Setup Menu To access the Quick Setup menuMenu Structure of Management Utility LAN IP Address LAN IP MaskWAN IP Address WAN IP MaskManagement Access Menu Default GatewayRead Protocol from DIP Switches ProtocolAdvanced Setup Menu Telnet PasswordTelnet Inactivity Timeout To access the Management Access menuTo access the Advanced Setup menu To access the Device Identification menuDevice Identification Menu Device NameInterface Parameters Menu Aging Timeout Maintenance ProtocolTo access the Protocol Parameters menu WAN Protocol Parameters Frame Relay Protocol MenuAuthentication Protocol WAN Protocol Parameters PPP Protocol MenuHeader and Control Field Compression Protocol Field CompressionPassword To Send Password To AcceptSecurity Host/Guest User Name To SendTo access the Multicast IP menu Multicast IP MenuMulticast Forwarding To access the Static Groups menu To access the Device Control menuDevice Control Menu Static GroupsTotal Timeout New Software Download MenuServer IP Address File NameView Error Log Screen Resets MenuReset Device Reset LANConfiguration and Connection Reset WANView Menu To access the ARP Tables screen To access the Multicast Groups Table screenARP Tables Multicast Groups Table ScreenTo access the Statistics menu Statistics ScreenDiagnostic Tool Ping Terminal Menu To access the Diagnostic Tools menuUsing the Ping Function To ping a hostErasing User’s Configuration To erase the user’s configurationErasing IR-IP Software Erasing Application SoftwareDownloading New Software Case, it is recommended to turn ASM-60 off and then back onTo download new software Appendix C IR-IP Interface Module Erasing IR-IP Software
Related manuals
Manual 90 pages 56.08 Kb

ASM-60 specifications

The RAD Data Communications ASM-60 is a highly advanced access and service management platform designed to streamline the deployment and management of various telecommunications services. It is particularly well-suited for carrier-grade applications, offering a robust solution that meets the demands of modern communication networks. The ASM-60 integrates multiple functionalities, ensuring that service providers can efficiently manage their networks and deliver high-quality services to their customers.

One of the standout features of the ASM-60 is its versatility. It supports a wide range of technologies, including Ethernet, TDM, and IP-based services. This adaptability allows service providers to seamlessly integrate legacy systems with newer technologies, ensuring a smooth transition as networks evolve. The platform is equipped to handle both synchronous and asynchronous services, catering to diverse customer needs while maximizing operational efficiency.

Reliability is paramount in telecommunications, and the ASM-60 excels in this regard. It boasts built-in redundancy features, ensuring continuous operation even in the event of a hardware failure. The platform is designed with hot-swappable components, allowing for maintenance and upgrades without disrupting service. This characteristic makes it an ideal choice for mission-critical applications that require uninterrupted service delivery.

In terms of scalability, the ASM-60 offers a comprehensive solution for growing networks. With its modular design, service providers can easily expand their infrastructure as demand increases. This scalability ensures that organizations can effectively respond to changing market conditions and customer requirements, facilitating long-term growth.

Another significant aspect of the ASM-60 is its advanced management capabilities. The platform is equipped with a user-friendly interface that simplifies configuration, monitoring, and troubleshooting tasks. It supports various management protocols, including SNMP and Command Line Interface (CLI), enabling seamless integration with existing network management systems.

Security is also a critical consideration in the design of the ASM-60. It features multiple layers of security, including encryption and authentication protocols, to safeguard sensitive data. This commitment to security helps service providers maintain the integrity and confidentiality of their customers’ information.

In conclusion, the RAD Data Communications ASM-60 is a powerful access and service management platform that meets the diverse needs of modern telecommunications networks. With its versatility, reliability, scalability, advanced management capabilities, and robust security features, the ASM-60 is an ideal choice for service providers looking to enhance their operational efficiency and deliver top-notch services to their customers.