RAD Data comm ASM-60 Transformers to the transmit and receive lines, Fuse 250A, slow-blow

Page 14

Chapter 1 IntroductionASM-60Installation and Operation Manual

Indicators

PWR (green)

Power

 

RTS (yellow)

Request to Send

 

TD (yellow)

Transmit Data

 

RD (yellow)

Receive Data

 

DCD (yellow)

Data Carrier Detect

 

TST (red)

Test

 

ALM (red)

Alarm

 

SYNC A (green/red)

Synchronization line A

 

SYNC B (green/red)

Synchronization line B

Physical

Height

44 mm / 1.7 in (1U)

 

Width

215 mm / 8.5 in

 

Depth

243 mm / 9.6 in

Power

Weight

1 kg / 3.1 lb

 

100 to 240 VAC ( 10%), 50 to 60 Hz, 6W

 

AC Voltage

±

 

Protection

AC/DC overvoltage protection circuits are connected via

 

 

transformers to the transmit and receive lines

 

Fuse

0.250A, slow-blow

Environment

Temperature

0–50°C / 32–122°F

 

Humidity

Up to 90%, non–condensing

1-6

Technical Specifications

Image 14
Contents ASM-60 International Headquarters RAD Data Communications IncPage Warranty Safety Warnings Ports Safety StatusConnecting the Interfaces Installing ASM-60Setting the Internal Switches Connecting the PowerNormal Indications Configuring ASM-60Operating ASM-60 Selecting the Data RateContents List of Figures Chapter Introduction OverviewManagement Real Time AlarmsDTE Interface Test CapabilitiesPhysical Description D View of ASM-60ASM-60 Block Diagram Functional DescriptionIR-IP IP router via RJ-45 connector Technical SpecificationsSupport via RJ-45 connector Interface 24/RS-232 TypeTransformers to the transmit and receive lines Fuse 250A, slow-blowChapter Installation and Setup Site Requirements and PrerequisitesPerforming the Internal Settings Package ContentsInstallation and Setup To install ASM-60Closing the ASM-60 Case Connecting the LineOpening the ASM-60 Case To connect the Hssi interface Connecting the DTEHssi Interface Connector Pinout To connect the AC power Installation and Setup Chapter Operation Front Panel IndicatorsASM-60 LED Indicators Name FunctionTurning Off ASM-60 ASM-60 Indicator StatusTurning On ASM-60 Preparing for the Control Session Control Port Interface CharacteristicsChapter Management from a Terminal Preparing TerminalTo initiate a control session Navigating the Management MenusInitiating a Control Session To choose an optionStarting the Control Session Terminal Management MenusTo display the Configuration menu Main MenuTo access the Display menu Displaying the ASM-60 System InformationDisplaying the ASM-60 Status To display the ASM-60 statusResetting ASM-60 To reset ASM-60Resetting ASM-60 Power-Up Self-Test Chapter DiagnosticsError Detection AlarmsTo access the log file Working with the Log FileTo display the Vdsl diagnostics Displaying the Vdsl Performance DiagnosticsASM-60 Alarms Number Terminal Message Description SeverityAfter the ASM-60 power-up ASM-60 Performance Monitoring ParametersTo run the LEDs test Running the Diagnostic TestsRunning the LEDs Test Running the Diagnostic Tests IR-ETH Connector Options Appendix a IR-ETH Interface ModuleLAN ProtocolInstallation and Operation Figure A-4. IR-ETH Layout UTP OptionConnecting to LAN DIP Switch SettingsLED Indicators Table A-2. DIP Switch SettingsIntroduction IR-ETH/QH ConnectorAppendix B IR-ETH/QH Interface Module Protocol Point-to-point Data Rate Kbps to 45 Mbps Table B-1 RJ-45 Connector PinoutPin Signal Function Section Name Description Possible Settings Factory Setting Setting the DIP SwitchTable B-2. DIP Switch Settings LED Name Color Description Location Connecting the LANTable B-3. IR-ETH/QH LED Indicators Appendix C IR-IP Interface Module OverviewStandard Conforms to Ieee 802.3/Ethernet Data Rate Delay FrameConnector 10BaseT UTP Shielded RJ-45 TopologyTable C-1. IR-IP LEDs Functions IR-IP DIP SwitchIR-IP LEDs Table C-3 RJ-45 PinoutIntroduction Accessing the IR-IP Management SubsystemIR-IP Management Subsystem, General Outline of Preliminary Configuration Performing Preliminary ConfigurationDefault IP Communication Parameters To perform the preliminary configuration procedureAssigning the Router LAN Interface Address Connecting the Telnet HostPreliminary Telnet Host Configuration IP Learning MechanismAssigning a LAN IP Address to a New IR-IP To view and edit the ARP table contentsTo configure the IP router LAN address No ping replies from IR-IP Changing the LAN IP Address of a Configured IR-IPWhat to Do If IP learning process is not successfulStarting a Management Utility General Operating ProceduresIR-IP Management Utility Menu Structure of Management Utility Quick Setup MenuTo access the Quick Setup menu WAN IP Address LAN IP AddressLAN IP Mask WAN IP MaskRead Protocol from DIP Switches Management Access MenuDefault Gateway ProtocolTelnet Inactivity Timeout Advanced Setup MenuTelnet Password To access the Management Access menuDevice Identification Menu To access the Advanced Setup menuTo access the Device Identification menu Device NameInterface Parameters Menu To access the Protocol Parameters menu Aging TimeoutMaintenance Protocol WAN Protocol Parameters Frame Relay Protocol MenuHeader and Control Field Compression Authentication ProtocolWAN Protocol Parameters PPP Protocol Menu Protocol Field CompressionSecurity Host/Guest Password To SendPassword To Accept User Name To SendMulticast Forwarding To access the Multicast IP menuMulticast IP Menu Device Control Menu To access the Static Groups menuTo access the Device Control menu Static GroupsServer IP Address Total TimeoutNew Software Download Menu File NameReset Device View Error Log ScreenResets Menu Reset LANView Menu Configuration and ConnectionReset WAN ARP Tables To access the ARP Tables screenTo access the Multicast Groups Table screen Multicast Groups Table ScreenTo access the Statistics menu Statistics ScreenDiagnostic Tool Ping Terminal Menu To access the Diagnostic Tools menuUsing the Ping Function To ping a hostErasing IR-IP Software Erasing User’s ConfigurationTo erase the user’s configuration Erasing Application SoftwareTo download new software Downloading New SoftwareCase, it is recommended to turn ASM-60 off and then back on Appendix C IR-IP Interface Module Erasing IR-IP Software
Related manuals
Manual 90 pages 56.08 Kb

ASM-60 specifications

The RAD Data Communications ASM-60 is a highly advanced access and service management platform designed to streamline the deployment and management of various telecommunications services. It is particularly well-suited for carrier-grade applications, offering a robust solution that meets the demands of modern communication networks. The ASM-60 integrates multiple functionalities, ensuring that service providers can efficiently manage their networks and deliver high-quality services to their customers.

One of the standout features of the ASM-60 is its versatility. It supports a wide range of technologies, including Ethernet, TDM, and IP-based services. This adaptability allows service providers to seamlessly integrate legacy systems with newer technologies, ensuring a smooth transition as networks evolve. The platform is equipped to handle both synchronous and asynchronous services, catering to diverse customer needs while maximizing operational efficiency.

Reliability is paramount in telecommunications, and the ASM-60 excels in this regard. It boasts built-in redundancy features, ensuring continuous operation even in the event of a hardware failure. The platform is designed with hot-swappable components, allowing for maintenance and upgrades without disrupting service. This characteristic makes it an ideal choice for mission-critical applications that require uninterrupted service delivery.

In terms of scalability, the ASM-60 offers a comprehensive solution for growing networks. With its modular design, service providers can easily expand their infrastructure as demand increases. This scalability ensures that organizations can effectively respond to changing market conditions and customer requirements, facilitating long-term growth.

Another significant aspect of the ASM-60 is its advanced management capabilities. The platform is equipped with a user-friendly interface that simplifies configuration, monitoring, and troubleshooting tasks. It supports various management protocols, including SNMP and Command Line Interface (CLI), enabling seamless integration with existing network management systems.

Security is also a critical consideration in the design of the ASM-60. It features multiple layers of security, including encryption and authentication protocols, to safeguard sensitive data. This commitment to security helps service providers maintain the integrity and confidentiality of their customers’ information.

In conclusion, the RAD Data Communications ASM-60 is a powerful access and service management platform that meets the diverse needs of modern telecommunications networks. With its versatility, reliability, scalability, advanced management capabilities, and robust security features, the ASM-60 is an ideal choice for service providers looking to enhance their operational efficiency and deliver top-notch services to their customers.