RAD Data comm ASM-60 Chapter Installation and Setup, Site Requirements and Prerequisites

Page 15

Chapter 2

Installation and Setup

This chapter describes installation and setup procedures for the standalone ASM-60 modem.

ASM-60 is delivered completely assembled. It is designed for tabletop or 19-inch rack installation.

After installing the unit:

Refer to Chapter 3 for the operating instructions.

Refer to Chapter 4 for the detailed system configuration procedures using ASCII terminal connected to the ASM-60 control port.

If a problem is encountered, refer to Chapter 5 for test and diagnostic instructions.

Internal settings, adjustment, maintenance, and repairs may be performed only by a skilled technician who is aware of the hazards involved.

Always observe standard safety precautions during installation, operation, and Warning maintenance of this product.

2.1 Site Requirements and Prerequisites

ASMi-60 is designed for installation as a desktop unit. A rack mount kit, K-28, for installation of ASM-60 in a 19-inch rack, is available upon special order.

AC-powered ASM-60 units should be installed within 1.5m (5 ft) of an easily-accessible grounded AC outlet capable of furnishing the voltage in accordance with ASM-60 nominal supply voltage.

Allow at least 90 cm (36 in) of frontal clearance for operating and maintenance accessibility. Allow at least 10 cm (4 in) clearance at the rear of the unit for signal lines and interface cables.

Caution Do not stack units on top of another.

The ambient operating temperature of ASM-60 should be 0 to 50°C (32 to 122°F), at a relative humidity of up to 90%, non-condensing.

Site Requirements and Prerequisites

2-1

Image 15
Contents International Headquarters RAD Data Communications Inc ASM-60Page Warranty Ports Safety Status Safety WarningsConnecting the Power Installing ASM-60Setting the Internal Switches Connecting the InterfacesSelecting the Data Rate Configuring ASM-60Operating ASM-60 Normal IndicationsContents List of Figures Overview Chapter IntroductionTest Capabilities Real Time AlarmsDTE Interface ManagementD View of ASM-60 Physical DescriptionFunctional Description ASM-60 Block DiagramInterface 24/RS-232 Type Technical SpecificationsSupport via RJ-45 connector IR-IP IP router via RJ-45 connectorFuse 250A, slow-blow Transformers to the transmit and receive linesSite Requirements and Prerequisites Chapter Installation and SetupTo install ASM-60 Package ContentsInstallation and Setup Performing the Internal SettingsConnecting the Line Opening the ASM-60 CaseClosing the ASM-60 Case Connecting the DTE Hssi Interface Connector PinoutTo connect the Hssi interface To connect the AC power Installation and Setup Name Function Front Panel IndicatorsASM-60 LED Indicators Chapter OperationASM-60 Indicator Status Turning On ASM-60Turning Off ASM-60 Preparing Terminal Control Port Interface CharacteristicsChapter Management from a Terminal Preparing for the Control SessionTo choose an option Navigating the Management MenusInitiating a Control Session To initiate a control sessionTerminal Management Menus Starting the Control SessionMain Menu To display the Configuration menuDisplaying the ASM-60 System Information To access the Display menuTo display the ASM-60 status Displaying the ASM-60 StatusTo reset ASM-60 Resetting ASM-60Resetting ASM-60 Alarms Chapter DiagnosticsError Detection Power-Up Self-TestWorking with the Log File To access the log fileNumber Terminal Message Description Severity Displaying the Vdsl Performance DiagnosticsASM-60 Alarms To display the Vdsl diagnosticsASM-60 Performance Monitoring Parameters After the ASM-60 power-upRunning the Diagnostic Tests Running the LEDs TestTo run the LEDs test Running the Diagnostic Tests Appendix a IR-ETH Interface Module IR-ETH Connector OptionsProtocol LANFigure A-4. IR-ETH Layout UTP Option Installation and OperationTable A-2. DIP Switch Settings DIP Switch SettingsLED Indicators Connecting to LANIR-ETH/QH Connector Appendix B IR-ETH/QH Interface ModuleIntroduction Table B-1 RJ-45 Connector Pinout Pin Signal FunctionProtocol Point-to-point Data Rate Kbps to 45 Mbps Setting the DIP Switch Table B-2. DIP Switch SettingsSection Name Description Possible Settings Factory Setting Connecting the LAN Table B-3. IR-ETH/QH LED IndicatorsLED Name Color Description Location Overview Appendix C IR-IP Interface ModuleTopology Delay FrameConnector 10BaseT UTP Shielded RJ-45 Standard Conforms to Ieee 802.3/Ethernet Data RateTable C-3 RJ-45 Pinout IR-IP DIP SwitchIR-IP LEDs Table C-1. IR-IP LEDs FunctionsAccessing the IR-IP Management Subsystem IR-IP Management Subsystem, GeneralIntroduction To perform the preliminary configuration procedure Performing Preliminary ConfigurationDefault IP Communication Parameters Outline of Preliminary ConfigurationIP Learning Mechanism Connecting the Telnet HostPreliminary Telnet Host Configuration Assigning the Router LAN Interface AddressTo view and edit the ARP table contents To configure the IP router LAN addressAssigning a LAN IP Address to a New IR-IP IP learning process is not successful Changing the LAN IP Address of a Configured IR-IPWhat to Do If No ping replies from IR-IPGeneral Operating Procedures IR-IP Management UtilityStarting a Management Utility Quick Setup Menu To access the Quick Setup menuMenu Structure of Management Utility WAN IP Mask LAN IP AddressLAN IP Mask WAN IP AddressProtocol Management Access MenuDefault Gateway Read Protocol from DIP SwitchesTo access the Management Access menu Advanced Setup MenuTelnet Password Telnet Inactivity TimeoutDevice Name To access the Advanced Setup menuTo access the Device Identification menu Device Identification MenuInterface Parameters Menu WAN Protocol Parameters Frame Relay Protocol Menu Aging TimeoutMaintenance Protocol To access the Protocol Parameters menuProtocol Field Compression Authentication ProtocolWAN Protocol Parameters PPP Protocol Menu Header and Control Field CompressionUser Name To Send Password To SendPassword To Accept Security Host/GuestTo access the Multicast IP menu Multicast IP MenuMulticast Forwarding Static Groups To access the Static Groups menuTo access the Device Control menu Device Control MenuFile Name Total TimeoutNew Software Download Menu Server IP AddressReset LAN View Error Log ScreenResets Menu Reset DeviceConfiguration and Connection Reset WANView Menu Multicast Groups Table Screen To access the ARP Tables screenTo access the Multicast Groups Table screen ARP TablesStatistics Screen To access the Statistics menuTo access the Diagnostic Tools menu Diagnostic Tool Ping Terminal MenuTo ping a host Using the Ping FunctionErasing Application Software Erasing User’s ConfigurationTo erase the user’s configuration Erasing IR-IP SoftwareDownloading New Software Case, it is recommended to turn ASM-60 off and then back onTo download new software Appendix C IR-IP Interface Module Erasing IR-IP Software
Related manuals
Manual 90 pages 56.08 Kb

ASM-60 specifications

The RAD Data Communications ASM-60 is a highly advanced access and service management platform designed to streamline the deployment and management of various telecommunications services. It is particularly well-suited for carrier-grade applications, offering a robust solution that meets the demands of modern communication networks. The ASM-60 integrates multiple functionalities, ensuring that service providers can efficiently manage their networks and deliver high-quality services to their customers.

One of the standout features of the ASM-60 is its versatility. It supports a wide range of technologies, including Ethernet, TDM, and IP-based services. This adaptability allows service providers to seamlessly integrate legacy systems with newer technologies, ensuring a smooth transition as networks evolve. The platform is equipped to handle both synchronous and asynchronous services, catering to diverse customer needs while maximizing operational efficiency.

Reliability is paramount in telecommunications, and the ASM-60 excels in this regard. It boasts built-in redundancy features, ensuring continuous operation even in the event of a hardware failure. The platform is designed with hot-swappable components, allowing for maintenance and upgrades without disrupting service. This characteristic makes it an ideal choice for mission-critical applications that require uninterrupted service delivery.

In terms of scalability, the ASM-60 offers a comprehensive solution for growing networks. With its modular design, service providers can easily expand their infrastructure as demand increases. This scalability ensures that organizations can effectively respond to changing market conditions and customer requirements, facilitating long-term growth.

Another significant aspect of the ASM-60 is its advanced management capabilities. The platform is equipped with a user-friendly interface that simplifies configuration, monitoring, and troubleshooting tasks. It supports various management protocols, including SNMP and Command Line Interface (CLI), enabling seamless integration with existing network management systems.

Security is also a critical consideration in the design of the ASM-60. It features multiple layers of security, including encryption and authentication protocols, to safeguard sensitive data. This commitment to security helps service providers maintain the integrity and confidentiality of their customers’ information.

In conclusion, the RAD Data Communications ASM-60 is a powerful access and service management platform that meets the diverse needs of modern telecommunications networks. With its versatility, reliability, scalability, advanced management capabilities, and robust security features, the ASM-60 is an ideal choice for service providers looking to enhance their operational efficiency and deliver top-notch services to their customers.