RAD Data comm ASM-60 Appendix B IR-ETH/QH Interface Module, Introduction, IR-ETH/QH Connector

Page 41

Appendix B

IR-ETH/QH Interface Module

B.1 Introduction

The IR-ETH/QH interface module includes a high performance self-learning Fast Ethernet bridge, which is connected to the LAN via a single 10BaseT or 100BaseT port, operating in full duplex and providing offer simple and cost-effective interconnection between 10/100BaseT LANs via VDSL links. The IR-ETH/QH interface module also supports IEEE 802.1/Q frames, enabling VLAN applications.

The module automatically learns MAC addresses of the LAN to which it is connected. Its LAN table stores up to 1,000 addresses with 5-minute automatic aging.

Filtering and forwarding is performed at the maximum theoretical rate of

150,000 packets per second (wire speed). The buffer with 1 Mb DRAM can hold 170 frames with a throughput latency of one frame. The forwarding of the broadcast and multicast messages from LAN to WAN can be disabled.

Figure B-1shows a typical application using ASM-60 with IR-ETH/QH module.

ASM-60ASM-60

Figure B-1. Typical Application of ASM-60 with IR-ETH/QH Module

B.2 IR-ETH/QH Connector

Figure B-2shows the rear panel of ASM-60, equipped with IR-ETH/QH module. Table B-1lists the module's RJ-45 connector pinout.

CAUTION : FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE AND RATING OF FUSE.

LINE

ACT LINK

100

A-1 2

4 5-B

Figure B-2. Rear Panel of ASM-60 with IR-ETH/QH Module

IR-ETH/QH Connector

B-1

Image 41
Contents International Headquarters RAD Data Communications Inc ASM-60Page Warranty Ports Safety Status Safety WarningsSetting the Internal Switches Installing ASM-60Connecting the Interfaces Connecting the PowerOperating ASM-60 Configuring ASM-60Normal Indications Selecting the Data RateContents List of Figures Overview Chapter IntroductionDTE Interface Real Time AlarmsManagement Test CapabilitiesD View of ASM-60 Physical DescriptionFunctional Description ASM-60 Block DiagramSupport via RJ-45 connector Technical SpecificationsIR-IP IP router via RJ-45 connector Interface 24/RS-232 TypeFuse 250A, slow-blow Transformers to the transmit and receive linesSite Requirements and Prerequisites Chapter Installation and SetupInstallation and Setup Package ContentsPerforming the Internal Settings To install ASM-60Closing the ASM-60 Case Connecting the LineOpening the ASM-60 Case To connect the Hssi interface Connecting the DTEHssi Interface Connector Pinout To connect the AC power Installation and Setup ASM-60 LED Indicators Front Panel IndicatorsChapter Operation Name FunctionTurning Off ASM-60 ASM-60 Indicator StatusTurning On ASM-60 Chapter Management from a Terminal Control Port Interface CharacteristicsPreparing for the Control Session Preparing TerminalInitiating a Control Session Navigating the Management MenusTo initiate a control session To choose an optionTerminal Management Menus Starting the Control SessionMain Menu To display the Configuration menuDisplaying the ASM-60 System Information To access the Display menuTo display the ASM-60 status Displaying the ASM-60 StatusTo reset ASM-60 Resetting ASM-60Resetting ASM-60 Error Detection Chapter DiagnosticsPower-Up Self-Test AlarmsWorking with the Log File To access the log fileASM-60 Alarms Displaying the Vdsl Performance DiagnosticsTo display the Vdsl diagnostics Number Terminal Message Description SeverityASM-60 Performance Monitoring Parameters After the ASM-60 power-upTo run the LEDs test Running the Diagnostic TestsRunning the LEDs Test Running the Diagnostic Tests Appendix a IR-ETH Interface Module IR-ETH Connector OptionsProtocol LANFigure A-4. IR-ETH Layout UTP Option Installation and OperationLED Indicators DIP Switch SettingsConnecting to LAN Table A-2. DIP Switch SettingsIntroduction IR-ETH/QH ConnectorAppendix B IR-ETH/QH Interface Module Protocol Point-to-point Data Rate Kbps to 45 Mbps Table B-1 RJ-45 Connector PinoutPin Signal Function Section Name Description Possible Settings Factory Setting Setting the DIP SwitchTable B-2. DIP Switch Settings LED Name Color Description Location Connecting the LANTable B-3. IR-ETH/QH LED Indicators Overview Appendix C IR-IP Interface ModuleConnector 10BaseT UTP Shielded RJ-45 Delay FrameStandard Conforms to Ieee 802.3/Ethernet Data Rate TopologyIR-IP LEDs IR-IP DIP SwitchTable C-1. IR-IP LEDs Functions Table C-3 RJ-45 PinoutIntroduction Accessing the IR-IP Management SubsystemIR-IP Management Subsystem, General Default IP Communication Parameters Performing Preliminary ConfigurationOutline of Preliminary Configuration To perform the preliminary configuration procedurePreliminary Telnet Host Configuration Connecting the Telnet HostAssigning the Router LAN Interface Address IP Learning MechanismAssigning a LAN IP Address to a New IR-IP To view and edit the ARP table contentsTo configure the IP router LAN address What to Do If Changing the LAN IP Address of a Configured IR-IPNo ping replies from IR-IP IP learning process is not successfulStarting a Management Utility General Operating ProceduresIR-IP Management Utility Menu Structure of Management Utility Quick Setup MenuTo access the Quick Setup menu LAN IP Mask LAN IP AddressWAN IP Address WAN IP MaskDefault Gateway Management Access MenuRead Protocol from DIP Switches ProtocolTelnet Password Advanced Setup MenuTelnet Inactivity Timeout To access the Management Access menuTo access the Device Identification menu To access the Advanced Setup menuDevice Identification Menu Device NameInterface Parameters Menu Maintenance Protocol Aging TimeoutTo access the Protocol Parameters menu WAN Protocol Parameters Frame Relay Protocol MenuWAN Protocol Parameters PPP Protocol Menu Authentication ProtocolHeader and Control Field Compression Protocol Field CompressionPassword To Accept Password To SendSecurity Host/Guest User Name To SendMulticast Forwarding To access the Multicast IP menuMulticast IP Menu To access the Device Control menu To access the Static Groups menuDevice Control Menu Static GroupsNew Software Download Menu Total TimeoutServer IP Address File NameResets Menu View Error Log ScreenReset Device Reset LANView Menu Configuration and ConnectionReset WAN To access the Multicast Groups Table screen To access the ARP Tables screenARP Tables Multicast Groups Table ScreenStatistics Screen To access the Statistics menuTo access the Diagnostic Tools menu Diagnostic Tool Ping Terminal MenuTo ping a host Using the Ping FunctionTo erase the user’s configuration Erasing User’s ConfigurationErasing IR-IP Software Erasing Application SoftwareTo download new software Downloading New SoftwareCase, it is recommended to turn ASM-60 off and then back on Appendix C IR-IP Interface Module Erasing IR-IP Software
Related manuals
Manual 90 pages 56.08 Kb

ASM-60 specifications

The RAD Data Communications ASM-60 is a highly advanced access and service management platform designed to streamline the deployment and management of various telecommunications services. It is particularly well-suited for carrier-grade applications, offering a robust solution that meets the demands of modern communication networks. The ASM-60 integrates multiple functionalities, ensuring that service providers can efficiently manage their networks and deliver high-quality services to their customers.

One of the standout features of the ASM-60 is its versatility. It supports a wide range of technologies, including Ethernet, TDM, and IP-based services. This adaptability allows service providers to seamlessly integrate legacy systems with newer technologies, ensuring a smooth transition as networks evolve. The platform is equipped to handle both synchronous and asynchronous services, catering to diverse customer needs while maximizing operational efficiency.

Reliability is paramount in telecommunications, and the ASM-60 excels in this regard. It boasts built-in redundancy features, ensuring continuous operation even in the event of a hardware failure. The platform is designed with hot-swappable components, allowing for maintenance and upgrades without disrupting service. This characteristic makes it an ideal choice for mission-critical applications that require uninterrupted service delivery.

In terms of scalability, the ASM-60 offers a comprehensive solution for growing networks. With its modular design, service providers can easily expand their infrastructure as demand increases. This scalability ensures that organizations can effectively respond to changing market conditions and customer requirements, facilitating long-term growth.

Another significant aspect of the ASM-60 is its advanced management capabilities. The platform is equipped with a user-friendly interface that simplifies configuration, monitoring, and troubleshooting tasks. It supports various management protocols, including SNMP and Command Line Interface (CLI), enabling seamless integration with existing network management systems.

Security is also a critical consideration in the design of the ASM-60. It features multiple layers of security, including encryption and authentication protocols, to safeguard sensitive data. This commitment to security helps service providers maintain the integrity and confidentiality of their customers’ information.

In conclusion, the RAD Data Communications ASM-60 is a powerful access and service management platform that meets the diverse needs of modern telecommunications networks. With its versatility, reliability, scalability, advanced management capabilities, and robust security features, the ASM-60 is an ideal choice for service providers looking to enhance their operational efficiency and deliver top-notch services to their customers.