Chapter 3: Installation and Setup

3. Installation and Initial Setup

This section describes how to install the Hardened Serial Server and configure the device.

NOTE: In this section, devices to be connected to the Hardened Serial Server’s serial connections are simply referred to as the “serial device.”

3.1 Connecting the Power Supply

Connect a DC power supply to the power terminals on the side of the Hardened Serial Server. Polarity of the wires is indicated underneath each connector. Acceptable voltages are between 10 VDC and 58 VDC. The power supply must be capable of supplying 4 watts for the LES421A or LES422A or 6 watts for the LES424A.

Figure 3-1. LES421A, LES422A, and LES424A power supply connections.

3.2 Connecting Hardened Serial Servers to Serial Devices

The Hardened Serial Servers can be connected to serial devices using RS-232, RS-422, RS-485 2-wire, or RS-485 4-wire communication. LES422A and LES424A models use (2) or (4) DB9 M connectors. LES421A models use either (1) DB9 M connector or (1) 5-position terminal strip.

3.2.1 RS-232

The 2- and 4-port models, along with the 1-port model when using its DB9M connector, support seven RS-232 signal lines (TD, RD, DTR, DSR, RTS, CTS, DCD) plus Signal Ground.

The 1-port model, when using its 5-position pluggable terminal block, supports four signal lines (TD, RD, RTS, CTS) plus Signal Ground.

NOTE: Only one connector (DB9M or 5-position terminal block) can be used on the LES421A.

Signals are single-ended and referenced to Signal Ground. Default communications parameters are 9600, 8, N, 1 (9600 baud, 8 data bits, no parity, 1 stop bit), and no flow control.

NOTE: The LES421A, LES422A, and LES424A are configured as DTEs. If they are connected to a computer or other DTE device, use a null-modem (crossover) cable. If the serial device is configured as a DCE, use a straight-through cable.

724-746-5500 blackbox.com

Page 17

Image 17
Contents 4-Port Hardened Serial Servers Trademarks Used in this Manual Trademarks Used in this ManualFCC and IC RFI Statements NOM Statement Table of Contents Table of Contents Serial Interface SpecificationsSpecifications General Network Network SpecificationsTCP/UDP Ports Configuration over TCPDimensional Diagrams Specifications Overview Introduction FeaturesOverview Hardware Description 1 1-Port Hardened Serial Server LES421A What‘s Included LES421A components 2 2-Port Hardened Serial Server LES422ALES422A components 3 4-Port Hardened Serial Server LES424ALES424A components Configuration SoftwareInstallation and Initial Setup Installation and SetupConnecting the Power Supply Connecting Hardened Serial Servers to Serial DevicesEthernet Passthrough Port 2 RS-4223 RS-485 Configuring via the Network using a Browser Installation and Initial SetupHardened Serial Server Configuration Direct IP and Virtual COM port connection Hardened Serial Server Operational ConnectionsPaired mode setup Installing and Starting Hardened Serial Server SoftwareDiscovering Hardened Serial Servers Icons Configuring the Hardened Serial ServerHardened Serial Server Information Table Configuration PaneLogging Login Click Login General Configuration page appearsSetting Up the Hardened Serial Server Name and Password Navigating the Configuration PagesChanging the Password Changing the Hardened Serial Servers NameSetting Up Static IP Addressing Setting Up IP AddressingSetting Up Dynamic IP Addressing TCP Configuration Setting Up Serial PortsSetting Up Port Network Parameters Configuring the Hardened Serial Server 11. TCP server settings UDP ConfigurationConfiguring the Hardened Serial Server Setting Up Paired Mode Operation Setting Up Virtual COM Vcom Operation16. IP addresses Configuring When Network Connections will be Forced Closed Configuring the Serial ServerSetting Up Advanced Network Settings Configuring when Data Packets are Sent Configuring the Hardened Serial Server Saving/Restoring the Configuration Settings Adding Virtual COM Ports Removing Virtual COM Ports Downloading Firmware Files Upgrading the Hardened Serial Server FirmwareUpgrading the Hardened Serial Server Firmware Uploading the Firmware to the Hardened Serial Server Operation Operation LED IndicatorsNetwork at the same IP address Front panel of the LES424A LEDs on the LES424A serial server Using the Reset Switch to Initiate a Hardware Reset Reset SwitchUsing the Reset Switch to Enter Console Mode Using the Reset Switch to Exit Console ModeTesting a Hardened Serial Server Connection DiagnosticsDiagnostics Testing a Hardened Serial Server Connection Testing a Virtual COM PortListing/Descriptions of Hardened Serial Server Settings Listing/Descriptions of Hardened Serial Server SettingsListing/Descriptions of Hardened Serial Server Settings TCP/IP properties OFF Listing/Descriptions of Hardened Serial Server Settings Listing/Descriptions of Hardened Serial Server Settings Appendix A. Default Server Settings Appendix a Default Server SettingsTerminal Block Appendix B Connector PinoutsAppendix B. Connector Pinouts DB9 M Connector Standard Ethernet Cable RJ-45 Pinout Blackbox.com Blackbox.com Blackbox.com Black Box Tech Support FREE! Live /7