Chapter 3: Installation and Initial Setup

In Virtual COM Port Mode, the serial ports on the serial server appear to applications running on the host PC as if the serial ports were physically located on the host PC. When a virtual COM port is configured on the PC (using Serial Server Software), a new COM port appears in the Device Manager. Windows programs are able to interface to the virtual COM port using standard Windows API calls. When a program on the PC opens the new COM port, it communicates directly with the remote serial device connected to the serial server.

In Paired Mode, two Hardened Serial Servers are used to provide a virtual cable connection between two remote serial devices using the Ethernet network. The end serial devices communicate data and handshake information directly, as if they were physically connected in a point-to-point serial connection. Paired Mode devices are set up as shown in the following diagram and configured using Hardened Serial Server Software or a web interface.

Network

Serial device

Serial device

Figure 3-7. Paired mode setup.

3.7 Installing and Starting Hardened Serial Server Software

Hardened Serial Server Software is a Windows-based application used to configure Hardened Serial Servers. Install it on your PC from the included CD. Installation should launch automatically when the CD is placed in the CD-ROM drive.

Follow the prompts to install the software.

Once the program is installed, go to the “Start > Programs” menu and run the program.

The Hardened Serial Server Software Discovery window appears.

Figure 3-8. Discovery window.

724-746-5500 blackbox.com

Page 21

Image 21
Contents 4-Port Hardened Serial Servers Trademarks Used in this Manual Trademarks Used in this ManualFCC and IC RFI Statements NOM Statement Table of Contents Table of Contents Specifications Specifications GeneralSerial Interface Network Network SpecificationsTCP/UDP Ports Configuration over TCPDimensional Diagrams Specifications Features OverviewOverview Introduction Hardware Description 1 1-Port Hardened Serial Server LES421A What‘s IncludedLES421A components 2 2-Port Hardened Serial Server LES422ALES422A components 3 4-Port Hardened Serial Server LES424ALES424A components Configuration SoftwareInstallation and Initial Setup Installation and SetupConnecting the Power Supply Connecting Hardened Serial Servers to Serial Devices2 RS-422 3 RS-485Ethernet Passthrough Port Installation and Initial Setup Hardened Serial Server ConfigurationConfiguring via the Network using a Browser Direct IP and Virtual COM port connection Hardened Serial Server Operational ConnectionsPaired mode setup Installing and Starting Hardened Serial Server SoftwareDiscovering Hardened Serial Servers Icons Configuring the Hardened Serial ServerHardened Serial Server Information Table Configuration PaneLogging Login Click Login General Configuration page appearsSetting Up the Hardened Serial Server Name and Password Navigating the Configuration PagesChanging the Password Changing the Hardened Serial Servers NameSetting Up IP Addressing Setting Up Dynamic IP AddressingSetting Up Static IP Addressing Setting Up Serial Ports Setting Up Port Network ParametersTCP Configuration Configuring the Hardened Serial Server 11. TCP server settings UDP ConfigurationConfiguring the Hardened Serial Server Setting Up Paired Mode Operation Setting Up Virtual COM Vcom Operation16. IP addresses Configuring the Serial Server Setting Up Advanced Network SettingsConfiguring When Network Connections will be Forced Closed Configuring when Data Packets are Sent Configuring the Hardened Serial Server Saving/Restoring the Configuration Settings Adding Virtual COM Ports Removing Virtual COM Ports Upgrading the Hardened Serial Server Firmware Upgrading the Hardened Serial Server FirmwareDownloading Firmware Files Uploading the Firmware to the Hardened Serial Server Operation Operation LED IndicatorsNetwork at the same IP address Front panel of the LES424A LEDs on the LES424A serial server Using the Reset Switch to Initiate a Hardware Reset Reset SwitchUsing the Reset Switch to Enter Console Mode Using the Reset Switch to Exit Console ModeDiagnostics DiagnosticsTesting a Hardened Serial Server Connection Testing a Hardened Serial Server Connection Testing a Virtual COM PortListing/Descriptions of Hardened Serial Server Settings Listing/Descriptions of Hardened Serial Server SettingsListing/Descriptions of Hardened Serial Server Settings TCP/IP properties OFF Listing/Descriptions of Hardened Serial Server Settings Listing/Descriptions of Hardened Serial Server Settings Appendix A. Default Server Settings Appendix a Default Server SettingsAppendix B Connector Pinouts Appendix B. Connector Pinouts DB9 M ConnectorTerminal Block Standard Ethernet Cable RJ-45 Pinout Blackbox.com Blackbox.com Blackbox.com Black Box Tech Support FREE! Live /7