Appendix A: Default Server Settings

Appendix A. Default Server Settings

 

Table A-1. Default server settings.

 

 

Setting

Default Value

 

 

Server Name

LES421A, LES422A, or LES424A

 

 

Serial Number

Printed on side of unit.

 

 

Password

Password field is blank from factory.

 

 

DHCP

Enable

 

 

IP Address

BASED ON DHCP SERVER

 

If a DHCP assignment is not available, the device will default to 169.254.102.39

 

 

Net Mask

255.255.255.0

 

 

Gateway

169.254.102.100

 

 

MAC Address

Fixed—see bottom label

 

 

Firmware Version

X.X.X (Current Version)

 

 

Hardware Version

X.X (Current Version)

 

 

Port

1, 2, 3, 4

 

 

Serial port mode

RS-232

 

 

Baud Rate

9600

 

 

Data bits

8

 

 

Parity

None

 

 

Stop bits

1

 

 

Flow Control

None

 

 

Protocol

TCP

 

 

Serial timeout

0 seconds

 

 

TCP alive timeout

0 minutes

 

 

Connection Mode

Server

 

 

Delimiter HEX 1

00

 

 

Delimiter HEX 2

00

 

 

Remove delimiters

Disable

 

 

Force transmit

0 ms

 

 

Inter-character timer

0 ms

 

 

Character count

0

 

 

Max connection

1

 

 

Page 54

724-746-5500 blackbox.com

Image 54
Contents 4-Port Hardened Serial Servers Trademarks Used in this Manual Trademarks Used in this ManualFCC and IC RFI Statements NOM Statement Table of Contents Table of Contents Specifications Specifications GeneralSerial Interface Network Specifications NetworkConfiguration over TCP TCP/UDP PortsDimensional Diagrams Specifications Features OverviewOverview Introduction What‘s Included Hardware Description 1 1-Port Hardened Serial Server LES421A2 2-Port Hardened Serial Server LES422A LES421A components3 4-Port Hardened Serial Server LES424A LES422A componentsConfiguration Software LES424A componentsConnecting the Power Supply Installation and SetupInstallation and Initial Setup Connecting Hardened Serial Servers to Serial Devices2 RS-422 3 RS-485Ethernet Passthrough Port Installation and Initial Setup Hardened Serial Server ConfigurationConfiguring via the Network using a Browser Hardened Serial Server Operational Connections Direct IP and Virtual COM port connectionInstalling and Starting Hardened Serial Server Software Paired mode setupDiscovering Hardened Serial Servers Configuring the Hardened Serial Server IconsConfiguration Pane Hardened Serial Server Information TableLogin Click Login General Configuration page appears LoggingChanging the Password Navigating the Configuration PagesSetting Up the Hardened Serial Server Name and Password Changing the Hardened Serial Servers NameSetting Up IP Addressing Setting Up Dynamic IP AddressingSetting Up Static IP Addressing Setting Up Serial Ports Setting Up Port Network ParametersTCP Configuration Configuring the Hardened Serial Server UDP Configuration 11. TCP server settingsConfiguring the Hardened Serial Server Setting Up Virtual COM Vcom Operation Setting Up Paired Mode Operation16. IP addresses Configuring the Serial Server Setting Up Advanced Network SettingsConfiguring When Network Connections will be Forced Closed Configuring when Data Packets are Sent Configuring the Hardened Serial Server Saving/Restoring the Configuration Settings Adding Virtual COM Ports Removing Virtual COM Ports Upgrading the Hardened Serial Server Firmware Upgrading the Hardened Serial Server FirmwareDownloading Firmware Files Uploading the Firmware to the Hardened Serial Server Operation LED Indicators OperationNetwork at the same IP address Front panel of the LES424A LEDs on the LES424A serial server Using the Reset Switch to Enter Console Mode Reset SwitchUsing the Reset Switch to Initiate a Hardware Reset Using the Reset Switch to Exit Console ModeDiagnostics DiagnosticsTesting a Hardened Serial Server Connection Testing a Virtual COM Port Testing a Hardened Serial Server ConnectionListing/Descriptions of Hardened Serial Server Settings Listing/Descriptions of Hardened Serial Server SettingsListing/Descriptions of Hardened Serial Server Settings TCP/IP properties OFF Listing/Descriptions of Hardened Serial Server Settings Listing/Descriptions of Hardened Serial Server Settings Appendix a Default Server Settings Appendix A. Default Server SettingsAppendix B Connector Pinouts Appendix B. Connector Pinouts DB9 M ConnectorTerminal Block Standard Ethernet Cable RJ-45 Pinout Blackbox.com Blackbox.com Blackbox.com Black Box Tech Support FREE! Live /7