Black Box 1-, 2-, and 4-Port Hardened Serial Servers Specifications General, Serial Interface

Page 7

Chapter 1: Specifications

1. Specifications

1.1 General

General Specifications

Certifications

FCC Part 15, Class A, CE, NEMA TS2, UL® Class 1, Division 2, Groups A, B, C, and D

 

 

Compatible Operating

Windows® XP (32/64 bit), 2003 Server (32/64 bit), Windows Vista® (32/64 bit), 2008 Server (32/64 bit), Windows 7 (32/64 bit)

Systems

 

 

 

Configuration Options

Via serial port using Hardened Serial Server Software, via network using Hardened Serial Server Software with an Ethernet connection

 

or a standard Web browser such as Internet Explorer® 7, 8, or 9, or Firefox® 3 or 4

 

 

Enclosure

Rating: IP30;

 

Mounting: DIN rail mount (35 mm)

 

 

User Controls

(1) Reset button

 

 

Connectors

LES421A: (1) DB9 M, (1) 5-pin terminal block, (1) RJ-45, (1) 2-position pluggable terminal block for power;

 

LES422A: (2) DB9 M, (1) RJ-45, (1) 2-position pluggable terminal block for power;

 

LES424A: (4) DB9 M, (1) RJ-45, (1) 3-position pluggable terminal block and (1) locking barrel connector for power

 

 

Indicators

LES421A: (4) LEDs: (1) Ready, (1) Serial, (1) Ethernet Link, (1) Ethernet Speed;

 

LES422A: (7) LEDs: (1) Ready, (2) Serial, (2) Ethernet Link, (2) Ethernet Speed;

 

LES424A: (9) LEDs: (1) Ready, (4) Serial, (2) Ethernet Link, (2) Ethernet Speed

 

 

Temperature Tolerance

Operating: -40 to +176° F (-40 to +80° C);

 

Storage: -40 to +185° F (-40 to +85° C);

 

Maximum Ambient Surrounding Air Temperature: 176° F (80° C)

 

 

Operating Humidity

10 to 95%, noncondensing

 

 

Power

LES421A, LES422A: 10 to 48 VDC (58 VDC max.), 4.0 watts max.;

 

LES424A: Locking barrel connector input: Voltage requirements: 10 to 30 VDC maximum, Class 2 grounded type supply only

 

NOTE: Coaxial power cable must be in accordance with Class 2 requirements in Article 725 of the NEC. The locking barrel connector

 

must not be used in a hazardous environment.

 

LES424A (continued): Consumption: 6.0 watts maximum;

 

Terminal blocks: Wire size: 28 to 16 AWG,

 

Wire Type: Copper wire only,

 

Tightening Torque: 5 kg-cm,

 

Wire Temperature Rating: 105° C minimum, sized for 60° C ampacity

 

NOTE: One conductor per terminal.

 

 

Size

LES421A, LES422A: 1.2"H x 3.2"W x 4.7"D (3 x 8.1 x 11.9 cm);

 

LES424A: 1.8"H x 4.4"W x 6.8"D (4.6 x 12.2 x 17.1 cm)

 

 

1.2 Serial Interface

Serial Interface Specifications

Baud Rates

75, 150, 300, 600, 1200, 2400, 4800, 7200, 9600, 14400, 19200, 28800, 38400, 57600, 115200, 230400

 

 

Data Bits

5, 6, 7, 8

 

 

Flow Control

None, RTS/CTS, X-ON, X-OFF

 

 

Mode Selection

RS-232/422/485 software-selectable

 

 

 

Parity

 

None, even, odd, mark, space

 

 

RS-232 Lines

TXD, RXD, RTS, CTS, DTR, DSR, DCD, GND

 

 

RS-422 Lines

TXDA(-), TXDB(+), RXDA(-), RXDB (+), GND

 

 

 

RS-485

(2-Wire)

Data(-), Data(+), GND

 

 

 

RS-485

(4-Wire)

TXDA(-), TXDB(+), RXDA(-), RXDB (+), GND

 

 

RS-422/485 Biasing

Auto 1 K-ohm pullups and pulldowns

 

 

RS-422/485 Termination

Termination with through hole (user supplied)

 

 

 

RS-485

Data Control

Auto control via Data Multipoint Control Unit (MCU)

 

 

Stop Bits

1, 1.5, 2

 

 

 

724-746-5500 blackbox.com

Page 7

Image 7
Contents 4-Port Hardened Serial Servers Trademarks Used in this Manual Trademarks Used in this ManualFCC and IC RFI Statements NOM Statement Table of Contents Table of Contents Specifications General SpecificationsSerial Interface Network Network SpecificationsTCP/UDP Ports Configuration over TCPDimensional Diagrams Specifications Overview FeaturesOverview Introduction Hardware Description 1 1-Port Hardened Serial Server LES421A What‘s IncludedLES421A components 2 2-Port Hardened Serial Server LES422ALES422A components 3 4-Port Hardened Serial Server LES424ALES424A components Configuration SoftwareConnecting Hardened Serial Servers to Serial Devices Installation and SetupInstallation and Initial Setup Connecting the Power Supply3 RS-485 2 RS-422Ethernet Passthrough Port Hardened Serial Server Configuration Installation and Initial SetupConfiguring via the Network using a Browser Direct IP and Virtual COM port connection Hardened Serial Server Operational ConnectionsPaired mode setup Installing and Starting Hardened Serial Server SoftwareDiscovering Hardened Serial Servers Icons Configuring the Hardened Serial ServerHardened Serial Server Information Table Configuration PaneLogging Login Click Login General Configuration page appearsChanging the Hardened Serial Servers Name Navigating the Configuration PagesSetting Up the Hardened Serial Server Name and Password Changing the PasswordSetting Up Dynamic IP Addressing Setting Up IP AddressingSetting Up Static IP Addressing Setting Up Port Network Parameters Setting Up Serial PortsTCP Configuration Configuring the Hardened Serial Server 11. TCP server settings UDP ConfigurationConfiguring the Hardened Serial Server Setting Up Paired Mode Operation Setting Up Virtual COM Vcom Operation16. IP addresses Setting Up Advanced Network Settings Configuring the Serial ServerConfiguring When Network Connections will be Forced Closed Configuring when Data Packets are Sent Configuring the Hardened Serial Server Saving/Restoring the Configuration Settings Adding Virtual COM Ports Removing Virtual COM Ports Upgrading the Hardened Serial Server Firmware Upgrading the Hardened Serial Server FirmwareDownloading Firmware Files Uploading the Firmware to the Hardened Serial Server Operation Operation LED IndicatorsNetwork at the same IP address Front panel of the LES424A LEDs on the LES424A serial server Using the Reset Switch to Exit Console Mode Reset SwitchUsing the Reset Switch to Initiate a Hardware Reset Using the Reset Switch to Enter Console ModeDiagnostics DiagnosticsTesting a Hardened Serial Server Connection Testing a Hardened Serial Server Connection Testing a Virtual COM PortListing/Descriptions of Hardened Serial Server Settings Listing/Descriptions of Hardened Serial Server SettingsListing/Descriptions of Hardened Serial Server Settings TCP/IP properties OFF Listing/Descriptions of Hardened Serial Server Settings Listing/Descriptions of Hardened Serial Server Settings Appendix A. Default Server Settings Appendix a Default Server SettingsAppendix B. Connector Pinouts DB9 M Connector Appendix B Connector PinoutsTerminal Block Standard Ethernet Cable RJ-45 Pinout Blackbox.com Blackbox.com Blackbox.com Black Box Tech Support FREE! Live /7