SMO-F551 / RMO-S551 Installation Guide
Installation Procedure on Silicon Graphics Systems
Test equipment:
The following procedure was confirmed with the following system and drive combination:
Host: | SGI O2 R5000, R10000 |
OS: | IRIX6.3 |
Target: |
Installation:
1)Connection
-Attach the drive to the host using a proper SCSI cable.
-Set proper SCSI ID on the MO drive. (In this case, SCSI ID = 4)
-Set proper termination.
Note: The SCSI ID number should be unique for each SCSI devices. The “hinv” command in the maintenance mode of the SGI workstation is useful to determine SCSI ID numbers.
2)Login
-Turn on the MO drive and host computer.
-Log in as root.
-Confirm the connection of MO drive and UNIX Workstation using following command.
Port2# #hinv –c scsi
Optical disk : unit 4 on SCSI controller 1
3)Media Initialization
-Launch the Unix Shell and insert a cartridge into the drive
-Enter
Format the media using following commands. port0 3# fx
fx version 6.3, July xx, 1998
fx: “device name“ = (dksc) [enter]
fx: ctlr# = (0) 1 [enter]
fx: drive# = (1) 4 [enter]
. . . opening dksc(1,4)
. . . controller test. . . OK
.
.
11