• Description of Indication History
History code number | Description | |
1st | 0 | The first error |
|
|
|
1st | 1 | Displays “00” |
1st | 2 | Displays “00” |
|
|
|
N | 0 | The last error |
|
|
|
N | 1 | Displays “00” |
|
|
|
N | 2 | Displays “00” |
|
|
|
0 | One error before the last. | |
|
|
|
1 | Displays “00” | |
|
|
|
2 | Displays “00” | |
|
|
|
0 | Two errors before the last. | |
|
|
|
1 | Displays “00” | |
|
|
|
2 | Displays “00” | |
|
|
|
R |
| Total recording time (Displays “0000” in this set) |
• Description of Error Indication Codes
Problem | Indication code | Meaning of code | Description |
|
|
|
|
No error | 00 | No error | Normal condition |
|
|
|
|
| 01 | Illegal access target address | Attempt to access an abnormal address |
| was specified |
| |
|
|
| |
Servo error | 02 | High temperture | High temperture |
|
|
|
|
| 03 | Focus error | Forcus could not be applied |
|
|
|
|
| 04 | Spindle error | Abnormal lotation of disc |
|
|
|
|
Power error | 22 | Low battery | Momentary interruption detected |
|
|
|
|
Reset the error display code
After servicing, reset the error display code.
1.Setting the test mode (see page 12).
2.Press the [DISPLAY] key activates the
3.To reset the error display code, press the X key (2 times) when the code is displayed (except “R 0000”). (All the data on the 1st, N,
– 15 –