Cisco Systems UCSSPENTVB200M3 specifications Removing a CPU and Heat Sink

Page 15

Server CIMC

2.1(3)

Server BIOS

2.1(3)

Cisco UCS Manager

2.1(3)

Board controller firmware

8.0

Do one of the following actions:

If your servers firmware and/or Cisco UCS Manager software are already at the required levels shown in the table above, you can replace the CPU hardware by using the procedures in this section.

If your servers firmware and/or Cisco UCS Manager software is earlier than the required levels, use the instructions in the Cisco UCS B-Series Servers Upgrade Guide for Intel E5-2600 v2 Series CPUs to upgrade your firmware and software. After you upgrade, return to the procedures in this book to replace the CPU and heatsink hardware.

Removing a CPU and Heat Sink

You will use these procedures to move a CPU from one server to another, to replace a faulty CPU, or to upgrade from one CPU to another.

Note The CPU pick and place tool is required to prevent damage to the connection pins between the motherboard and the CPU. Do not attempt this procedure without the required tool, which is included with each CPU option kit.

Procedure

Step 1 Unscrew the four captive screws securing the heat sink to the motherboard. See callout 1.

Loosen one screw by a quarter turn, then move to the next in the X pattern shown in the following figure. Continue loosening until the heat sink can be lifted off.

Step 2 Remove the heat sink (UCSB-HS-01-EP). See callout 2.

Remove the existing thermal compound from the bottom of the heat sink using the cleaning kit (UCSX-HSCK= ) included with each CPU option kit. Follow the instructions on the two bottles of cleaning solvent.

15

Image 15
Contents Cisco UCS B200 M3 Blade Server Installation and Service Note LEDs Cisco UCS B200 M3 Blade ServerColor Description LEDConnectors Hard Drive ReplacementButtons RAID Considerations Removing a Blade Server Hard DriveInstalling a Blade Server Hard Drive Blade Server Removal and InstallationRemoving a Blade Server Powering Off Blade Servers Using the Power ButtonPositioning a Blade Server in the Chassis Installing a Half-width Blade ServerRemoving a Blade Server Cover Secure Digital SD Card AccessOpening a Cisco UCS B200 M3 Blade Server Cisco UCS B200 M3 Air Baffles Air BafflesInternal Components Diagnostics Button and LEDsWorking Inside the Blade Server Installing a Motherboard Cmos BatteryLocation of the Motherboard Cmos Battery CPU and Heatsink ReplacementRemoving a CPU and Heat Sink Step Removing the Heat Sink and Accessing the CPU SocketInstalling a New CPU and Heat Sink Protective Cap Removal Lift the tool and CPU straight up off of the pedestal Using the CPU Pick and Place Tool to Insert the CPU Replacing the Heat Sink B200 M3 Shown Memory and Performance Installing MemorySupported DIMMs Installing DIMMs in the Blade ServerDIMMs and Channels Memory ArrangementPhysical Representation of DIMMs and Channels Figure below shows a logical view of the DIMMs and channels DIMMs per CPU CPU 1 installed slots CPU 2 installed slots Memory PerformanceMemory Mirroring and RAS Installing an mLOM Installing a Modular LOMInstalling an Adapter Card Enabling a Trusted Platform Module Installing an Adapter CardServer Troubleshooting Specification ValueRelated Documentation Obtaining Documentation and Submitting a Service Request Page USA

UCSSPENTVB200M3 specifications

Cisco Systems has long been a stalwart in the networking and telecommunications industry, offering a comprehensive range of products designed to enhance connectivity and communication for businesses around the globe. One such standout product is the Cisco UCSSPENTVB200M3. This model is part of Cisco's Unified Computing System (UCS), specifically tailored for environments requiring reliable and efficient data center solutions.

The Cisco UCSSPENTVB200M3 is characterized by its robust architecture that seamlessly integrates computing, networking, and storage resources in a single platform. This convergence is a significant advantage, as it simplifies management and reduces deployment costs. One of the primary features of this model is its scalability, allowing organizations to easily adjust their resources as their needs evolve. Whether a company is expanding, scaling down, or optimizing its operations, the UCS system provides the flexibility needed to maintain operational efficiency.

In terms of technology, the UCSSPENTVB200M3 employs Intel's Xeon processors, which are known for their powerful performance and energy efficiency. This choice of hardware ensures that the system can handle intense workloads and provides the computational power necessary for data-intensive applications. Additionally, the system supports advanced virtualization technologies that enhance its capabilities, enabling multiple operating systems and applications to run on a single physical server, which maximizes resource utilization.

Another noteworthy characteristic of the UCSSPENTVB200M3 is its advanced security features. As data breaches become increasingly common, Cisco has prioritized the protection of information within its products. This model includes integrated security features that safeguard sensitive data and ensure compliance with industry regulations.

Connectivity is also a critical component of this system, featuring multiple network interfaces that support high-speed communication. This is essential for businesses that rely on real-time data transfer and cloud-based services. Furthermore, the UCS Manager interface simplifies the management of server resources, allowing administrators to automate tasks and maintain optimal performance with ease.

Overall, the Cisco UCSSPENTVB200M3 is an exceptional solution for modern data centers, offering a combination of performance, scalability, security, and ease of management. This product stands as a testament to Cisco's commitment to innovation and its ability to meet the demands of today's dynamic business landscape. With organizations increasingly relying on technology for growth, systems like the UCSSPENTVB200M3 are vital for driving efficiency and competitiveness in the digital age.