TAG SV-2000-X2 manual Core Competences Engineering, Manufacturing and Integration

Page 4

Operations Manual

2.2Core Competences

2.2.1 Engineering

TAG’s engineering methodology is built upon Multi-Disciplinary Optimization (MDO) and rigorous design reviews. Although PMs drive the schedule at TAG, Engineering leverages Computer-Aided Design (CAD) tools, Computational Fluid Dynamics (CFD) models, rapid prototyping processes, and diverse test equipment and facilities to ensure requirements are being met at every step of the design. TAG Engineering follows a proven design-review process, ensuring all entrance and exit criteria are met at each stage. Rigorous documentation is compiled to demonstrate requirement compliance, risks are mitigated, and decisions are prudent – throughout the design process.

TAG prides itself on its engineering laboratories and facilities. Over the past three years, TAG has invested in several pieces of equipment that allow TAG to test and certify products directly onsite to the harshest environmental requirements of military standards – including the MIL-STD-810F and DO 160D.

TAG’s onsite test equipment currently includes a Highly Accelerated Lifecycle Testing (HAL T) Chamber, an Electromagnetic Interference (EMI) test chamber, and a high-/low-te mperature thermal test chamber. TAG’s facility also provides:

Floor plan designed to support a cellular manufacturing model with modular assembly lines

A dedicated 24-hour system burn-in room

A modern production status tracking and Enterprise Resource Planning (ERP) system with external web collaboration capabilities

Dedicated Quality Assurance workstations for system compliance and validation inspection

2.2.2 Manufacturing and Integration

TAG implements Cellular Manufacturing processes through our compartmentalized, state-of-the- art production facility to minimize waste byproducts and maximize production efficiency. TAG’s manufacturing facility is physically partitioned to model the major philosophies of Lean Manufacturing. Consistent with the model, each of TAG’s production cells are capable of operating in isolation; however personnel and tools are shared across all cells to streamline manufacturing operations, costs, and the production/integration schedule. TAG’s floor

SV-2000-X2 Server (CENTRIX / JHSV)

 

Part Number: 1008080

Page 4 of 82

Version 1.4. 01/12/2010

 

Image 4
Contents SV-2000-X2 Server Centrix / Jhsv Operations Manual Copyright 2008 Technology Advancement Group, Inc TAG TrademarksAbout TAG Summary of QualificationsCore Competences Engineering Manufacturing and IntegrationLifecycle Management About TAG Summary of Qualifications Core CompetenciesPage Date Version Number Updated By Description Document Revision HistoryScope and Audience About This ManualOrganization Table of Contents RAID List of Figures 1SV-2000-X2 Front View11 Stripe Size Chapter Safety Instructions Types of warnings used in this manualPage SV-2000-X2 2U Server Server Overview Product InformationSpecifications Chassis & power supply Motherboard and On-board FeaturesSV-2000-X2 Server Fan Controller Processor & CacheAdditional specifications 3 SV-2000-X2 Server HighlightsServer Components 4 SV-2000-X2 ServerMotherboard Model and Type Power Management Identifying your I/O ConnectorsSystem Memory Identifying System MemoryFloppy Drives Standard Server ComponentsScsi HP 920 LTO-3 Ultrium tape drive 5Internal Tape Drive 3 D/DVD DriveInput Power Line Frequency Dual-redundant, auto-sensing power supplyPower Connector 7Hot-Swap Power Supply PCI I/O Expansion Cards Adaptec 5805 SAS/SATA RAID ControllerAdaptec 29320 ALP-R Scsi Controller 9Adaptec 29320 ALP-R Scsi ControllerProcedures Procedures Identifying Server Components Using Device ManagerServer Startup Server Shutdown1Control Panel Double-click the System icon. Figure Page Working with Device Properties 4Device ManagerPage Installing and Removing Hardware in Windows Using the Add New Hardware Wizard6Control Panel Double-click the Add Hardware icon. Figure Installing Legacy Peripherals Removing Legacy Peripherals9System Properties Click the Hardware tab 10Device Manger TAG Approved Bios Common Bios SettingsHard Drives Boot Sector Virus Boot SequencePasswords MemoryPlug and Play Bios Bios Configuration for SV-2000-X2 12Load Optimized Defaults 13Enhanced Intel 14Enhanced Intel, Disable 15Processor Confirmation Screen 16Deep C-state Support Screen 17USB Configuration 18Intel Virtualization Technology 19Save and Reset 20Grounding Wrist Strap Replacing a Hot-Swap Power Supply Module Replacing a Hot-Swap Hard Drive 11.1 146GB SAS Hard Drive Removing the Server CoverInstall system memory Unlatch both Dimm socket levers, as shown in FigureReplacing the Cmos Battery Ultrium 920 Tape Drive Install Tape DriveRemove Tape Drive Page RAID RAID RAID DefinedRAID Level 1Array Configuration Create a RAID 5 Array On AdaptecPage Initialized 6Create Array 7Select Drives Page Page Page Page Page 13Cache Functionality 14Write Caching Page Operations Manual Press Enter to continue. Figure 17Cache Warning 18Hot Spare Check 19 Exit Utility About RAID Global and Hot Spares Global and Dedicated Hot SparesContact