Plasmon FS3102 manual RAID Verify, Stripe Size, Stripe Unit Size, Caching

Page 29

If there are insufficient disks to form an entire new row, the RAID will be expanded by adding columns to the stripe. This involves adding extra disks to each row (this will be a single row unless the RAID has already been expanded by adding an additional row). When this is done, a re-striping operation is necessary. The system reads each stripe in turn and writes it to an expanded stripe. This is a time consuming operation.

NOTE: Expansion by column will expand the RAID using the same disk capacity that was used in the existing columns. If the disks that are being used to expand the RAID have smaller capacities than the columns already in the RAID, the expansion will not be allowed. If the disks that are being used to expand the RAID have larger capacities than the columns already in the RAID, the additional capacity on the larger disks will be lost.

RAID Verify

A RAID level 5 may be checked for valid parity by initiating a verify operation. The system reads each stripe and checks for valid parity. At the end of the verify process the system sends an Alert if any stripes were found with invalid parity.

Stripe Size

Each RAID can consist of up to a maximum of 12 disks.

Stripe Unit Size

The stripe unit size is set by the profile. See the Raidtec Manager specification for more details.

Caching

The Raidtec FS3102 comes with 256 MB of cache memory as standard. The system supports up to 1 GB as an option. The cache memory is used for both read and write data. There are three kinds of caching implemented by the system firmware.

Read Cached Data

The system records the number of read and write commands that occur in the same physical stripe. When the number of commands exceeds a preset threshold, the system will allocate storage space to cache this data. This increases performance because subsequent read operations can be serviced from memory instead of reading from the disk.

Streaming Read Data

The system records the starting block and block size of each SCSI command received. When the start block of a new command matches the last block of a previous command the system detects that there is a stream of commands in progress and prefetches data up to 16 times the size of the original command. This increases performance by lowering the latency of subsequent commands in the stream.

Write Cached Data

When write caching is enabled, good status is returned immediately, before the data is written to disk. This increases performance in two ways. Firstly it lowers command latency to the host. Secondly, by coalescing contiguous write data into larger segments before it is written to disk, seeks are reduced and bandwidths increased.

Raidtec FS3102 Hardware Installation Guide

Version 1.0

29

Image 29
Contents FS3102 Hardware Installation Guide Safety and Emissions Appendix D Supported Disk Drives Default IP Address Introduction PrefaceDisclaimer Trademarks ModificationsFCC Booklet Information FCC Radio Frequency Interference StatementShielded Cables ComplianceFS3102 System Overview Raidtec FS3102 Block DiagramContact service personnel for assistance if General Precautions and Electrical ConsiderationsCleaning Instructions Safety and Emissions Unpacking Familiarising yourself with the systemOutlines the standard kit supplied with a Raidtec FS3102 What’s in the boxSystem Views System Front View System LED IndicatorsSystem Back View Controller IndicatorsIndicator Colour Description Installing SFPs Optical transceivers Installing the FS3102 systemInstalling Disk Drives SFP Removal Installing a Host Bus Adaptor HBASFP Replacement Cabling the Host and the FS3102 Single Port/Host DAS ConfigurationDual Port, Single Host SAN configuration Dual Port, Multi Host DAS Configuration Configuring the FS3102 Battery Pack Replacement Policy Battery Backup Unit BBUBBU Indicators Data Hold TimeReplaceable Field Replaceable Units FRUs10Plasmon Technical Support Failure Events Appendix a AlertsBBU Notifications Alert MessagesPage Logical Volumes Appendix B RAID FeaturesRAID Levels RAID CreationStripe Size RAID VerifyStripe Unit Size CachingAuto Rebuild DisabledPriority BackgroundEnvironmental Conditions Appendix C System SpecificationsElectrical Characteristics Weight Mechanical SpecificationsDimensions Air FlowSupported Drive List Appendix D Supported Disk DrivesAppendix E Ethernet Interface References Default IP AddressSupported Interfaces Supported ProtocolsFCC