Plasmon manual FS3102 System Overview, Raidtec FS3102 Block Diagram

Page 7

2 FS3102 System Overview

The Raidtec FS3102 2Gb FC-SATA RAID system includes the following pieces:

2Gb FC-SATA RAID controller that supports up to 16 SATA disk drives (only 12 are used in this product), two 2Gb FC target interfaces using SFPs and a 1 Gb Ethernet port for connectivity (management software and email alerts)

o 256 MB of cache memory (1 GB optional)

Battery Backup Unit (BBU) for maintaining power to the cache memory during power failures (optional)

2U 12 bay enclosure with two redundant PSU modules, three redundant fan modules and a backplane

SATA disk drives in shuttles

oCapacities supported are 250 GB, 400 GB and 500 GB

Raidtec Manager Management Software for managing the RAID system

oJava Application that runs on a host system

SATA HDD 1

 

3 Blowers

SATA HDD 2

 

 

Backplane

SATA II

Controller

 

 

 

 

Dual PSU

SATA HDD 12

 

Optional BBU

Figure 2-1: Raidtec FS3102 Block Diagram

Dual

2 Gb FC

Gigabit Ethernet

Raidtec FS3102 Hardware Installation Guide

Version 1.0

7

Image 7
Contents FS3102 Hardware Installation Guide Safety and Emissions Appendix D Supported Disk Drives Default IP Address Trademarks Modifications PrefaceIntroduction DisclaimerCompliance FCC Radio Frequency Interference StatementFCC Booklet Information Shielded CablesFS3102 System Overview Raidtec FS3102 Block DiagramContact service personnel for assistance if General Precautions and Electrical ConsiderationsCleaning Instructions Safety and Emissions Unpacking Familiarising yourself with the systemOutlines the standard kit supplied with a Raidtec FS3102 What’s in the boxSystem Views System Front View System LED IndicatorsSystem Back View Controller IndicatorsIndicator Colour Description Installing Disk Drives Installing the FS3102 systemInstalling SFPs Optical transceivers SFP Replacement Installing a Host Bus Adaptor HBASFP Removal Dual Port, Single Host SAN configuration Single Port/Host DAS ConfigurationCabling the Host and the FS3102 Dual Port, Multi Host DAS Configuration Configuring the FS3102 Data Hold Time Battery Backup Unit BBUBattery Pack Replacement Policy BBU IndicatorsReplaceable Field Replaceable Units FRUs10Plasmon Technical Support Failure Events Appendix a AlertsBBU Notifications Alert MessagesPage RAID Creation Appendix B RAID FeaturesLogical Volumes RAID LevelsCaching RAID VerifyStripe Size Stripe Unit SizeBackground DisabledAuto Rebuild PriorityElectrical Characteristics Appendix C System SpecificationsEnvironmental Conditions Air Flow Mechanical SpecificationsWeight DimensionsSupported Drive List Appendix D Supported Disk DrivesSupported Protocols Default IP AddressAppendix E Ethernet Interface References Supported InterfacesFCC