Plasmon FS3102 manual Installing a Host Bus Adaptor HBA, SFP Removal, SFP Replacement

Page 17

In the event that the SFPs need to be changed, carry out the following procedure’s while referring to Figure 6-4

Controller

SFP

SFP Handle

Figure 6-4

6.2.1SFP Removal

1.Remove the SFP from the controller by lowering the SFP handle to the down position.

2.Gripping the handle, slide the SFP out from the controller fully.

6.2.2SFP Replacement

1.With the SFP handle in the lowered position, align the SFP to the controller port and insert fully until you feel the connector engaging.

2.Turn the handle up until it clicks to the home position (ref: Figure 6-5)

SFP

Figure 6-5

6.3Installing a Host Bus Adaptor (HBA)

Install the prescribed host bus adaptor in the host computer using the documented procedure supplied by the host computer manufacturer.

Raidtec FS3102 Hardware Installation Guide

Version 1.0

17

Image 17
Contents FS3102 Hardware Installation Guide Safety and Emissions Appendix D Supported Disk Drives Default IP Address Introduction PrefaceDisclaimer Trademarks ModificationsFCC Booklet Information FCC Radio Frequency Interference StatementShielded Cables ComplianceFS3102 System Overview Raidtec FS3102 Block DiagramContact service personnel for assistance if General Precautions and Electrical ConsiderationsCleaning Instructions Safety and Emissions Unpacking Familiarising yourself with the systemOutlines the standard kit supplied with a Raidtec FS3102 What’s in the boxSystem Views System Front View System LED IndicatorsSystem Back View Controller IndicatorsIndicator Colour Description Installing SFPs Optical transceivers Installing the FS3102 systemInstalling Disk Drives SFP Removal Installing a Host Bus Adaptor HBASFP Replacement Cabling the Host and the FS3102 Single Port/Host DAS ConfigurationDual Port, Single Host SAN configuration Dual Port, Multi Host DAS Configuration Configuring the FS3102 Battery Pack Replacement Policy Battery Backup Unit BBUBBU Indicators Data Hold TimeReplaceable Field Replaceable Units FRUs10Plasmon Technical Support Failure Events Appendix a AlertsBBU Notifications Alert MessagesPage Logical Volumes Appendix B RAID FeaturesRAID Levels RAID CreationStripe Size RAID VerifyStripe Unit Size CachingAuto Rebuild DisabledPriority BackgroundEnvironmental Conditions Appendix C System SpecificationsElectrical Characteristics Weight Mechanical SpecificationsDimensions Air FlowSupported Drive List Appendix D Supported Disk DrivesAppendix E Ethernet Interface References Default IP AddressSupported Interfaces Supported ProtocolsFCC