2 SafeCom Go Canon
2.9.2Older Canon devices
1.Open a web browser and enter the IP address of the MFP in the address field followed by :8000/sms. Example:
http://172.16.6.55:8000/sms
Use of JavaScript (Active Scripting) must be enabled in the browser.
2.Enter Password. The default SMS password is: MeapSmsLogin.
3.Click Log In.
Stop and uninstall SafeCom Go:
4.In the browser in the Application List select SafeCom Go. Click Stop.
5.In the Application List select SafeCom Go. Click Uninstall.
6.Click OK.
Change Login Service to Default Authentication:
7.Click on the System Management tab.
8.Click on the Enhanced Sys. App tab.
9.In the Login Service section select Default Authentication. Click Select.
Restart the MFP:
10.On the control panel press and hold the power button to restart the MFP. Uninstall SafeCom Go Login:
11.In the browser click on the System Management tab.
12.Click on the Enhanced Sys. App tab.
13.In the Login Service section select SafeCom Go Login. Click Uninstall.
14.Click OK.