PRODUCT SPECIFICATIONS
Shock and Vibration
PARAM ETER | OPER AT ING | N | |
|
|
|
|
Mechanical Shoc k | 30 Gs, 2.0 ms , no errors | 300 | Gs, 2.0 ms , no damage |
|
|
| |
Rotational Shoc k |
| 20,000 Rad/sec ,0.5 to 1.0 ms , no d | |
|
|
| |
Random Vibration | 10 to 45 Hz at 0.004 G2/Hz | PSD : | |
| 48 to 62 Hz at 0.008 G2/Hz | 10 Hz at .05 G2/Hz | |
| 65 to 300 Hz at 0.004 G2/Hz | 20 Hz at .055 G2/Hz, | |
| 301 to 500 Hz at 0.0006 G2/Hz | 300 | Hz at .05 G2/Hz |
| no errors | 301 | Hz at .0014 G2/Hz |
|
| 500 | Hz at .001 G2/Hz |
|
| 760 | Hz at .001 G2/Hz |
|
| 877 | Hz at .003 G2/Hz |
|
| 1000 Hz at .001 G2/Hz | |
|
| 1570 Hz at .001 G2/Hz | |
|
| 2000 Hz at .0001 G2/Hz | |
Swept Sine Vibration |
|
|
|
10 to 300 Hz | 1 G (0 to peak ) amplitude, 1 octave per minute |
|
|
Reliability Specifications
Annual Return Rate |
|
< 0.5% | Annual Return Rate (ARR) indicates the average against products shipped. |
| ARR includes all reasons for returns (failures, handling damage, NDF), but |
| does not include inventory credit returns. |
Quality Acceptance Rate |
|
<1,000 DPPM | The quality acceptance rate indicates the percentage of Maxtor products |
| successfully installed by our customers, and/or the number of defective parts |
| per million (DPPM) encountered during the entire installation process. |
Start/Stop Cycles |
|
>50,000 | This indicates the average minimum cycles for reliable start/stop function. |
Load/Unload Cycles |
|
>100,000 | This indicates the average minimum cycles for reliable load/unload function. |
Data Reliability |
|
<1 per 10E15 bits read | Data errors |
| recovery features activated. |
Component Design Life |
|
5 years (minimum) | Component design life is defined as a.) the time period before identified |
| |
|