FieldServer FS-8700-31 Report Adapter Configuration, Report Network Manager Configuration

Page 16

FS-8700-31 Siemens TIWAY I

Page 13 of 23

The above map descriptor will continuously execute the indicated host adapter command and will store the following parameter values in the data array “HIU_Config”:

Offset Parameter

0Dipswitch 1 and 2 settings

1Config flag ( 0 = HIU not configured, 1 = HIU configured )

2Option 01 configuration value

3Option 02 configuration value

4Option 03 configuration value

4.4.6.3.Report Adapter Configuration

Reports the Adapter Configuration option values that was used to configure the adapter.

Map_Descriptor_Name,

Data_Array_Name,

Data_Array_Offset,

Function,

Node_name,

TIWAY_Host_Adapter_Cmd,

Length,

C39_REP_ADAP_CONFIG,

Adapter_Config,

0,

RDBC,

PLC_01,

Report_Adapter_Config,

6,

Scan_Interval

 

 

 

 

 

 

0s

 

 

 

 

 

 

The above map descriptor will continuously execute the indicated host adapter command and will store the following parameter values in the data array “Adapter_Config”:

Offset Parameter

0Dipswitch 1 and 2 settings

1Config flag ( 0 = Adapter not configured, 1 = Adapter configured )

2Option 01 configuration value

3Option 02 configuration value

4Option 03 configuration value

5Option 04 configuration value

4.4.6.4.Report Network Manager Configuration

Reports the Network Manager option values that was used to configure the network manager.

Map_Descriptor_Name,

Data_Array_Name, Data_Array_Offset, Function, Node_name, TIWAY_Host_Adapter_Cmd, Length,

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com

Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: support@fieldserver.com

Image 16
Contents FS-8700-31 Siemens Tiway Effective for all systems manufactured after May 1Table of Contents Advanced Topics Driver Notes Troubleshooting tips Siemens Tiway I Driver Description FieldServer Mode Nodes CommentsFS-8700-31 Siemens Tiway IPage 1 Required 3rd Party Configuration Provided by the Supplier of 3rd Party Equipment HardwareRequired 3rd Party Software Optional ItemsConfiguring the FieldServer as a Tiway Client Hardware ConnectionsHardware Connection Tips / Hints Data Arrays/DescriptorsClient Side Connection Descriptions Section TitleColumn Title Function Legal Values ExampleClient Side Node Descriptors FS-8700-31 Siemens Tiway ExampleDriver Related Map Descriptor Parameters Bit word datatypesBit byte datatypes Bit float datatypesBit datatypes Timing ParametersPacked-bit datatypes Reading data from random PLC data memory locations Reading secondary PLC status Writing data to random PLC data memory locations C18FLOATPLC254 Report HIU Configuration Tiway host adapter command map descriptor examplesRead Secondary Log Report Adapter Configuration Report Network Manager ConfigurationSoft Reset Forces the Unilink Host Adapter to do a software resetDisconnect Secondaries Reset AdapterConnect Secondaries FS-8700-31 Siemens Tiway Server Side Connection Descriptors Configuring the FieldServer as a Tiway ServerFS-8700-931 Siemens Tiway Server Side Node Descriptors FS-8700-931 Siemens Tiway ExampleDriver Specific Map Descriptor Parameters Bit float datatypes Serving Tiway data map descriptor example Serving DrumCountPreset Tiway data map descriptor exampleServing PLC status data map descriptor example Advanced Topics Troubleshooting tips Connection Tips & HintsDriver Notes FS-8700-31 Siemens Tiway IPage 23 Date Driver Document Resp Comment Version Revision