FieldServer FS-8700-31 Soft Reset, Forces the Unilink Host Adapter to do a software reset

Page 17

FS-8700-31 Siemens TIWAY I

 

 

 

 

Page 14 of 23

C40_REP_NM_CONFIG,

Nm_Config,

0,

RDBC,

PLC_01,

Report_NM_Config,

16,

Scan_Interval

 

 

 

 

 

 

0s

 

 

 

 

 

 

The above map descriptor will continuously execute the indicated host adapter command and will store the following parameter values in the data array “Nm_Config”:

Offset Parameter

0Dipswitch 1 and 2 settings

1Config flag ( 0 = Network Manager not configured, 1 = Network Manager configured )

2Option 01 configuration value

3Option 02 configuration value

4Option 03 configuration value

5Option 04 configuration value

6Option 05 configuration value

7Option 06 configuration value

8Option 07 configuration value

9Option 08 configuration value

10Option 09 configuration value

11Option 0A configuration value

12Option 0B configuration value

13Option 0C configuration value

14Option 0D configuration value

15Option 0E configuration value

4.4.6.5.Soft Reset

Forces the UNILINK Host Adapter to do a software reset.

Map_Descriptor_Name,

Data_Array_Name, Data_Array_Offset,

Function,

Node_name,

TIWAY_Host_Adapter_Cmd,

Length

C41_SOFT_RESET,

Cmd_Triggers,

0,

AWT,

PLC_01,

Soft_Reset,

1

The above map descriptor will execute the indicated host adapter command once every time a value is written to the data array “Cmd_Triggers” at offset 0.

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: support@fieldserver.com

Image 17
Contents Effective for all systems manufactured after May 1 FS-8700-31 Siemens TiwayTable of Contents Advanced Topics Driver Notes Troubleshooting tips FS-8700-31 Siemens Tiway IPage 1 FieldServer Mode Nodes CommentsSiemens Tiway I Driver Description Provided by the Supplier of 3rd Party Equipment Hardware Required 3rd Party ConfigurationRequired 3rd Party Software Optional ItemsHardware Connections Configuring the FieldServer as a Tiway ClientHardware Connection Tips / Hints Data Arrays/DescriptorsSection Title Client Side Connection DescriptionsColumn Title Function Legal Values ExampleFS-8700-31 Siemens Tiway Example Client Side Node DescriptorsBit word datatypes Driver Related Map Descriptor ParametersBit byte datatypes Bit float datatypesPacked-bit datatypes Timing ParametersBit datatypes Reading data from random PLC data memory locations Reading secondary PLC status Writing data to random PLC data memory locations C18FLOATPLC254 Read Secondary Log Tiway host adapter command map descriptor examplesReport HIU Configuration Report Network Manager Configuration Report Adapter ConfigurationForces the Unilink Host Adapter to do a software reset Soft ResetConnect Secondaries Reset AdapterDisconnect Secondaries FS-8700-31 Siemens Tiway FS-8700-931 Siemens Tiway Configuring the FieldServer as a Tiway ServerServer Side Connection Descriptors FS-8700-931 Siemens Tiway Example Server Side Node DescriptorsDriver Specific Map Descriptor Parameters Bit float datatypes Serving PLC status data map descriptor example Serving DrumCountPreset Tiway data map descriptor exampleServing Tiway data map descriptor example Driver Notes Troubleshooting tips Connection Tips & HintsAdvanced Topics Date Driver Document Resp Comment Version Revision FS-8700-31 Siemens Tiway IPage 23