FieldServer FS-8700-31 instruction manual Reading secondary PLC status

Page 12

FS-8700-31 Siemens TIWAY I

Page 9 of 23

Preset_Step_List,

Scan_Interval

 

5 8 9 33 49,

0s

 

The above map descriptor will continuously read 5 data elements from addresses 0-4 of type

“Drum_Count_Preset” from PLC_01. The Preset Steps associated with addresses are (address 0):5, (address 1):8, (address 2):9, (address 3):33, and (address 4):49. The data will be stored contiguously in the data array from offset 70.

4.4.4.4.Reading Drum_Count_Preset data from random PLC data memory locations

Map_Descriptor_Name,

Data_Array_Name,

Data_Array_Offset,

Function,

Node_name,

TIWAY_Data_Type, TIWAY_Address_List,

C08_RAW16_PLC01,

RAW16_Data,

75,

RDBC,

PLC_01,

Drum_Count_Preset, 5 9,

Length,

Preset_Step_List, Scan_Interval

 

 

 

 

2,

42 22,

0s

 

 

 

 

The above map descriptor will continuously read 2 data elements from addresses 5 and 9 of type

“Drum_Count_Preset” from PLC_01. The Preset Steps associated with addresses are (address 5):42 and (address 9):22. The data will be stored in the data array at offset 75 and 76.

4.4.4.5.Reading secondary PLC status

Map_Descriptor_Name, Data_Array_Name,

Data_Array_Offset,

Function,

Node_name,

TIWAY_Data_Type,

Length,

Scan_Interval

C36_STATUS_PRIM,

Status,

0,

RDBC,

PLC_01,

Status_Primitive,

3,

0s

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com

Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: support@fieldserver.com

Image 12
Contents FS-8700-31 Siemens Tiway Effective for all systems manufactured after May 1Table of Contents Advanced Topics Driver Notes Troubleshooting tips FieldServer Mode Nodes Comments Siemens Tiway I Driver DescriptionFS-8700-31 Siemens Tiway IPage 1 Required 3rd Party Configuration Provided by the Supplier of 3rd Party Equipment HardwareRequired 3rd Party Software Optional ItemsConfiguring the FieldServer as a Tiway Client Hardware ConnectionsHardware Connection Tips / Hints Data Arrays/DescriptorsClient Side Connection Descriptions Section TitleColumn Title Function Legal Values ExampleClient Side Node Descriptors FS-8700-31 Siemens Tiway ExampleDriver Related Map Descriptor Parameters Bit word datatypesBit byte datatypes Bit float datatypesTiming Parameters Bit datatypesPacked-bit datatypes Reading data from random PLC data memory locations Reading secondary PLC status Writing data to random PLC data memory locations C18FLOATPLC254 Tiway host adapter command map descriptor examples Report HIU ConfigurationRead Secondary Log Report Adapter Configuration Report Network Manager ConfigurationSoft Reset Forces the Unilink Host Adapter to do a software resetReset Adapter Disconnect SecondariesConnect Secondaries FS-8700-31 Siemens Tiway Configuring the FieldServer as a Tiway Server Server Side Connection DescriptorsFS-8700-931 Siemens Tiway Server Side Node Descriptors FS-8700-931 Siemens Tiway ExampleDriver Specific Map Descriptor Parameters Bit float datatypes Serving DrumCountPreset Tiway data map descriptor example Serving Tiway data map descriptor exampleServing PLC status data map descriptor example Troubleshooting tips Connection Tips & Hints Advanced TopicsDriver Notes FS-8700-31 Siemens Tiway IPage 23 Date Driver Document Resp Comment Version Revision