FieldServer FS-8700-31 Reset Adapter, Disconnect Secondaries, Connect Secondaries

Page 18

FS-8700-31 Siemens TIWAY I

Page 15 of 23

4.4.6.6.Reset Adapter

Forces the UNILINK Host Adapter to do a hardware reset.

Map_Descriptor_Name,

Data_Array_Name, Data_Array_Offset,

Function,

Node_name,

TIWAY_Host_Adapter_Cmd,

Length

C42_RESET_ADAPTER,

Cmd_Triggers,

1,

AWT,

PLC_01,

Reset_Adapter,

1

The above map descriptor will execute the indicated host adapter command once every time a value is written to the data array “Cmd_Triggers” at offset 1.

4.4.6.7.Disconnect Secondaries

Disconnect Secondary PLCs from the network.

Map_Descriptor_Name,

Data_Array_Name,

Data_Array_Offset,

Function,

Node_name,

TIWAY_Host_Adapter_Cmd,

Length,

C43_DISC_SECDS,

Cmd_Triggers,

2,

AWT,

PLC_01,

Disconnect_Secondaries,

1,

Secondaries_List

 

 

 

 

 

 

1 9 147 254

 

 

 

 

 

 

The above map descriptor will execute the indicated host adapter command once every time a value is written to the data array “Cmd_Triggers” at offset 2. Secondaries 1 9 147 and 254 will be disconnected from the network.

To disconnect all secondaries, use only one value of 255 in the Secondaries_List field.

4.4.6.8.Connect Secondaries

Disconnect Secondary PLCs from the network.

Map_Descriptor_Name,

Data_Array_Name,

Data_Array_Offset,

Function,

Node_name,

TIWAY_Host_Adapter_Cmd,

Length,

C45_CONNECT_SECDS,

Cmd_Triggers,

4,

AWT,

PLC_01,

Connect_Secondaries,

1,

Secondaries_List

 

 

 

 

 

 

1 9 147 254

 

 

 

 

 

 

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com

Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: support@fieldserver.com

Image 18
Contents FS-8700-31 Siemens Tiway Effective for all systems manufactured after May 1Table of Contents Advanced Topics Driver Notes Troubleshooting tips FieldServer Mode Nodes Comments Siemens Tiway I Driver DescriptionFS-8700-31 Siemens Tiway IPage 1 Required 3rd Party Software Required 3rd Party ConfigurationProvided by the Supplier of 3rd Party Equipment Hardware Optional ItemsHardware Connection Tips / Hints Configuring the FieldServer as a Tiway ClientHardware Connections Data Arrays/DescriptorsColumn Title Function Legal Values Client Side Connection DescriptionsSection Title ExampleClient Side Node Descriptors FS-8700-31 Siemens Tiway ExampleBit byte datatypes Driver Related Map Descriptor ParametersBit word datatypes Bit float datatypesTiming Parameters Bit datatypesPacked-bit datatypes Reading data from random PLC data memory locations Reading secondary PLC status Writing data to random PLC data memory locations C18FLOATPLC254 Tiway host adapter command map descriptor examples Report HIU ConfigurationRead Secondary Log Report Adapter Configuration Report Network Manager ConfigurationSoft Reset Forces the Unilink Host Adapter to do a software resetReset Adapter Disconnect SecondariesConnect Secondaries FS-8700-31 Siemens Tiway Configuring the FieldServer as a Tiway Server Server Side Connection DescriptorsFS-8700-931 Siemens Tiway Server Side Node Descriptors FS-8700-931 Siemens Tiway ExampleDriver Specific Map Descriptor Parameters Bit float datatypes Serving DrumCountPreset Tiway data map descriptor example Serving Tiway data map descriptor exampleServing PLC status data map descriptor example Troubleshooting tips Connection Tips & Hints Advanced TopicsDriver Notes FS-8700-31 Siemens Tiway IPage 23 Date Driver Document Resp Comment Version Revision