FieldServer FS-8700-31 instruction manual Table of Contents

Page 2

FS-8700-31 Siemens TIWAY I

Index

TABLE OF CONTENTS

1.

Siemens TIWAY I Driver Description

1

2.

Driver Scope of Supply

2

2.1.

 

Supplied by FieldServer Technologies for this driver

2

2.2.

 

Provided by the Supplier of 3rd Party Equipment

2

2.2.1.

Hardware

2

2.2.2. Required 3rd Party Software

2

2.2.3. Required 3rd Party Configuration

2

2.2.4.

Optional Items

2

3.

Hardware Connections

3

3.1.

 

Hardware Connection Tips / Hints

3

4.

Configuring the FieldServer as a TIWAY Client

3

4.1.

 

Data Arrays/Descriptors

3

4.2.

 

Client Side Connection Descriptions

4

4.3.

 

Client Side Node Descriptors

5

4.4.

 

Client Side Map Descriptors

5

4.4.1. FieldServer Related Map Descriptor Parameters

5

4.4.2. Driver Related Map Descriptor Parameters

6

4.4.3.

Timing Parameters

7

4.4.4.

Reading TIWAY data map descriptor examples

8

 

4.4.4.1. Reading data from contiguous PLC data memory locations

8

 

4.4.4.2. Reading data from random PLC data memory locations

8

4.4.4.3.Reading Drum_Count_Preset data from contiguous PLC data memory locations 8

4.4.4.4. Reading Drum_Count_Preset data from random PLC data memory locations

..9

4.4.4.5. Reading secondary PLC status

9

4.4.5. Writing TIWAY data map descriptor examples

10

4.4.5.1.

Writing data to contiguous PLC data memory locations

10

4.4.5.2.

Writing data to random PLC data memory locations

10

4.4.5.3.Writing the same value to a block of contiguous PLC data memory locations .11

4.4.5.4.Writing Drum_Count_Preset data to contiguous PLC data memory locations .11

 

4.4.5.5. Writing Drum_Count_Preset data to random PLC data memory locations

11

4.4.6. TIWAY host adapter command map descriptor examples

12

 

4.4.6.1.

Read Secondary Log

12

 

4.4.6.2.

Report HIU Configuration

12

 

4.4.6.3.

Report Adapter Configuration

13

 

4.4.6.4. Report Network Manager Configuration

13

 

4.4.6.5.

Soft Reset

14

 

4.4.6.6.

Reset Adapter

15

 

4.4.6.7.

Disconnect Secondaries

15

 

4.4.6.8.

Connect Secondaries

15

5.

Configuring the FieldServer as a TIWAY Server

17

5.1.

Server Side Connection Descriptors

17

5.2.

Server Side Node Descriptors

18

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: support@fieldserver.com

Image 2
Contents FS-8700-31 Siemens Tiway Effective for all systems manufactured after May 1Table of Contents Advanced Topics Driver Notes Troubleshooting tips FS-8700-31 Siemens Tiway IPage 1 FieldServer Mode Nodes CommentsSiemens Tiway I Driver Description Required 3rd Party Software Required 3rd Party ConfigurationProvided by the Supplier of 3rd Party Equipment Hardware Optional ItemsHardware Connection Tips / Hints Configuring the FieldServer as a Tiway ClientHardware Connections Data Arrays/DescriptorsColumn Title Function Legal Values Client Side Connection DescriptionsSection Title ExampleClient Side Node Descriptors FS-8700-31 Siemens Tiway ExampleBit byte datatypes Driver Related Map Descriptor ParametersBit word datatypes Bit float datatypesPacked-bit datatypes Timing ParametersBit datatypes Reading data from random PLC data memory locations Reading secondary PLC status Writing data to random PLC data memory locations C18FLOATPLC254 Read Secondary Log Tiway host adapter command map descriptor examplesReport HIU Configuration Report Adapter Configuration Report Network Manager ConfigurationSoft Reset Forces the Unilink Host Adapter to do a software resetConnect Secondaries Reset AdapterDisconnect Secondaries FS-8700-31 Siemens Tiway FS-8700-931 Siemens Tiway Configuring the FieldServer as a Tiway ServerServer Side Connection Descriptors Server Side Node Descriptors FS-8700-931 Siemens Tiway ExampleDriver Specific Map Descriptor Parameters Bit float datatypes Serving PLC status data map descriptor example Serving DrumCountPreset Tiway data map descriptor exampleServing Tiway data map descriptor example Driver Notes Troubleshooting tips Connection Tips & HintsAdvanced Topics FS-8700-31 Siemens Tiway IPage 23 Date Driver Document Resp Comment Version Revision